Skip to content

Lektrico/ha_lektrico

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

53 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

hacs_badge

Custom Component for Home Assistant.

LEKTRI.CO

Lektrico Charging Station

This custom integration allows you to manage your Lektrico EV Charger and your Lektrico Load Balancer device that are in your wifi network.

Installation

Configuration can be done on UI.

Lektrico devices are discoverable with Zeroconf.

You can also add manually the device if you know its IP.

Installation steps:

  1. You must have Home Assistant and HACS (Home Assistant Community Store) installed.
  2. Download the "Lektrico Charging Station" integration from HACS. (don't forget to restart Home Assistant after the download)
  3. Go to Settings -> Devices & Services and you should see there all Lektrico devices that are currently online in your wifi network.

Supported entities for EV Charger

Entity name Entity type Values' type Accepted values Description
Authentication switch boolean true/false Defines if the charger requires authentication or just plug in the connector and it will charge.
Charge start button - - Sends the command to start charging.
Charge stop button - - Sends the command to stop charging.
Charging time sensor integer - Current session charging time in s
Current sensor double - Current value.
Dynamic limit number integer 0-32 Dynamic current value. 0: Pause charging process. 6 - 32: Resume charging process with current limited to value.
Energy sensor double - Current session charged energy in Wh.
Errors binary_sensor boolean - Flag to specify if the charger has active errors. Has attributes that shows: State e activated, Overtemp, Critical temp, Overcurrent, Meter fault, Undervoltage error, Overvoltage error, Rcd error, Cp diode failure, Contactor failure.
ForceSinglePhase switch boolean - Force single phase (only L1) charging. Parameter is volatile and not saved in flash, meaning it will be reset to false after a reboot.
Installation current sensor integer - Current value [A] to be limited by software. Set according to electrical installation.
Led brightness number integer 10 - 100 LED maximum brightness in %.
Lifetime energy sensor integer - Total charged energy [kWh].
Limit reason sensor string - Current limit reason. Values: No limit, Installation current, User limit, Dynamic limit, Schedule, EM offline, EM, OCPP, Overtemperature, Switching phases, 1P Charging Disabled
Lock switch boolean true/false Specify if the charger is locked or not. If set to true, no charging session will be started.
Power sensor double - Current instant power in W.
Reboot button - - Reset device. If a charging session is active, the device will wait for its end first.
State sensor string - Charger state. Values: Available, Connected, Authentication, Charging, Error, Updating, Locked, Paused.
Temperature sensor double - Board temperature.
User limit number integer 6-32 User current.
Voltage sensor double - Current voltage value.

Supported entities for Load Balancer device

Entity name Entity type Values’ type Accepted values Description
Breaker current sensor integer - Main breaker current. This will be the maximum current the household is allowed to use.
Current sensor double - Measured current.
LB mode select integer 0 – 3 Load balancing mode. Values: 0-Off, 1-Power, 2-Hybrid, 3-Green.
PF sensor double - Power factor.
Power sensor double - Measured active power.
Reboot button - - Reset device.
Voltage sensor double - Measured voltage.

Device Info

  • Name
  • Serial Number
  • Revision
  • Producer
  • Firmware