Firmware for the Rhizome

Anything that should be imported into Particle Build as a "Library" is in the lib directory. Examples of possible .ino file configurations are in the firmware directory.

Semi-local build

You can use the Particle CLI tool in conjunction with a local IDE to build the project using the provided CMakeLists.txt file. Simply add a build directory to the project directory and navigate to it via the terminal. Then run cmake .. and the build should get punted off to Particle. If all goes well, you'll get a binary file that you can then flash to your Core/Photon using particle flash DEVICEID firmware.bin

Note that if you do this, you'll need to have CMake. If you're using CLion, CMake should be bundled within the IDE directory somewhere.

#Adding Temperature Sensors (One Wire protocol) It is recommended that to add a probe, connect all probes you will be using and then run the displayProbeIds() function located in Ohmbrewer::Onewire. make note of which probes are located at which index location, you may also wish to record the probe ID (may be useful in future releases). NOTE: if you change the probes attached or the number of probes attached the index value MAY change. So any time the configuration is changed, double check by rerunning the above protocol.

REST API

The Rhizome supports a number of RESTful operations to support management and operation of Equipment and Equipment Groupings attached to it. These operations are accessible via the Particle CLI and curl as specified in the Particle.function documentation. They're also provide the interface Ohmbrewer uses to manage and control the Rhizome.

The available functions and their argument patterns are as follows. Please note that all argument strings must be provided as comma-delimited Strings with no spaces.

  • add - Add Equipment
    • Format: TYPE,ID,[PINS]
      • TYPE: The Equipment type

        Type Type Name
        Temperature Sensor temp
        Relay relay
        Pump pump
        Heating Element heat
        Thermostat therm
        RIMS rims
      • ID: The ID of the desired Equipment

      • PINS: One or more pins that will be logically grouped as representing the Equipment. Order depends on Equipment Type:

        Type Pins
        Temperature Sensor Index†
        Relay Power Pin
        Pump Power Pin
        Heating Element Control Pin, Power Pin*
        Thermostat Sensor Index†, Element Control Pin, Element Power Pin*
        RIMS Therm Sensor Index†,Thermostat Control Pin, Thermostat Power Pin*,
                                  Recirculation Pump Power Pin, Safety Sensor Index† |
        
        • In the event that a Heating Element only uses one pin, please provide -1 for the Power Pin. This applies to any Power Pin marked with a (*) above.
        • † Currently, we expect all Temperature Sensors to be OneWire probes. we use the same pin for all Temperature Sensors.
        • Note that currently we do not provide a way to actually change the Bus Pin (we always assume it's D0). This may change in the future. Until then, we won't do anything with any of the provided Bus Pins.
        • Note that all index locations are One Wire index locations on the onewire sensors list.
        • Also note that currently we do not support adding bare Relays. That may change in future releases, so the expect API is included above.
    • Expected result:
      • Success: Particle.function returns the ID number.
      • Failure: Particle.function returns a negative number indicating the cause of the failure.
  • remove - Remove Equipment
    • Format: TYPE,ID
      • TYPE: The Equipment type
      • ID: The ID of the desired Equipment
    • Expected result:
      • Success: The specified Equipment instance is removed from the Rhizome's memory and Particle.function returns the ID number.
      • Failure: Particle.function returns a negative number indicating the cause of the failure.
  • update - Update Equipment state
    • Format: TYPE,ID,CURRENT_TASK,STOP_TIME{,OTHER}
      • TYPE: The Equipment type (see add above)

      • ID: The ID of the desired Equipment

      • CURRENT_TASK: The Task ID for the current operation, typically from Ohmbrewer. (string)

      • STATE: state of the equipment.

      • STOP_TIME: Some time in the future at which to switch the Equipment to the OFF state. This should be provided as an Integer value representing the time in Unix time / Epoch time.

      • OTHER: Zero or more additional arguments. These arguments are generally optional.

        Type Additional arguments
        Thermostat target Temp, Sensor state, Element state
        RIMS Safety Sensor state, Pump state{, Thermostat arguments (as above)}
        • All states should be either ON or OFF
        • If you wish to skip a given argument but provide a later argument, you must provide --. For example, to set the state of a Thermostat's Element to ON without changing it's Sensor's state, the argument string would be therm,1,someuuid,999999,--,ON
    • Expected result:
      • Success: Particle.function returns the ID number.
      • Failure: Particle.function returns a negative number indicating the cause of the failure.
  • index - Report current Equipment (not yet implemented)
    • Format: TYPE
      • TYPE: The Equipment type (optional)
    • Expected result:
      • Success: Particle.function returns the number of Equipment instances in the Sprout list and a status report containing information about current pin settings and state for all Equipment is published to the Rhizome's event stream. If TYPE is supplied, only information about that type of Equipment is returned.
      • Failure: Particle.function returns a negative number indicating the cause of the failure.
  • info - Report settings for a particular Equipment instance (not yet implemented)
    • Format: TYPE,ID
      • TYPE: The Equipment type
      • ID: The ID of the desired Equipment
    • Expected result:
      • Success: Particle.function returns the ID number and a status report containing information about current pin settings and state is published to the Equipment's event stream.
      • Failure: Particle.function returns a negative number indicating the cause of the failure.

As with all things, if this interface isn't working as expected, please consult the code (or other generated documentation) as this README may not be the most up-to-date source of information. (We'll try super hard though. Promise.)

Releases

No releases published

Packages