fix bmi088: set correct accel scale #17467

Merged
merged 1 commit into from
Apr 27, 2021
Merged

fix bmi088: set correct accel scale #17467

merged 1 commit into from
Apr 27, 2021

Conversation

bkueng
Copy link
Member

@bkueng bkueng commented Apr 27, 2021

This affected the clipping limit, which was set too low.
Other drivers are correct.

This affected the clipping limit, which was set too low
@dagar
Copy link
Member

dagar commented Apr 27, 2021

I assumed the bmi055 would have been wrong as well, but it looks correct.

@dagar dagar added bug Drivers 🔧 Sensors, Actuators, etc labels Apr 27, 2021
@dagar dagar merged commit 1a89f16 into master Apr 27, 2021
@dagar dagar deleted the fix_bmi088_accel_range branch April 27, 2021 14:27