Skip to content

Imports meter readings of Kamstrup Multical 66C to Home Assistant (www.home-assistant.io) or sends them to a MQTT broker

License

Notifications You must be signed in to change notification settings

RuntimeError123/hass-mc66c

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

39 Commits
 
 
 
 
 
 
 
 

Repository files navigation

hass-mc66c

Imports meter readings of Kamstrup Multical 66C to Home Assistant or MQTT.

Author: RuntimeError123 / L. Bosch

MIT License

Copyright © 2019 RuntimeError123 / L. Bosch

Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.

1. INTRODUCTION

This script was written to be able to request data (meter readings) from a Kamstrup Multical 66C meter. This meter was provided by Nuon (utility company) to record the energy consumption for the district heating (which we call 'stadsverwarming' in Dutch) in my home. The meter is not connected to the smart meter in my home, nor it has a serial port which I am able to connect a home automation solution to. There are no connectors visible. This script uses an infrared read/write head to communicate with the meter. Because the meter is battery powered, this will eventually drain the battery. According to the Kamstrup Multical 66C meter manual the normal battery life of the main battery should be somewhere around 10 years. This will be shorter when the meter is requested to transmit it's readings every few minutes. I am using this script to update the readings every 30 minutes in Home Assistant. The script can be run with two configurations. It uses an MQTT broker (Home Asssistance integrated or stand alone) to send the measurements. All values are sent to a single MQTT topic. Home Assistant will be able to create separate sensors on a single MQTT topic. For testing purposes, this script can also output to the screen.

2. REQUIREMENTS

To run, this script requires Python 3 with the following modules to be installed:

  • serial (installable with apt-get install python3-serial)
  • requests
  • json
  • time
  • yaml (can be installed with apt-get install python3-yaml)

To use this script with MQTT, install Paho MQTT (apt-get install python3-pip && pip3 install paho-mqtt).

When this script is configured to use SSL/TLS, the Python SSL module is required.

To get the meter readings, you will need an IR interface. I am currently using the IR Schreib Lesekopf (infrared read write head) from Volkszaehler (https://wiki.volkszaehler.org/hardware/controllers/ir-schreib-lesekopf) which I recommend.

3. INSTALLATION

Place the files from Git in a separate folder (e.g. /home/homeassistant/stadsverwarming). Edit the config.yaml file according to your situation. Please see next paragraph for more information. Test the script by running it using python3 stadsverwarming.py . When it is not executed by root (which I would strongly recommend) the user running this script must have permission to use serial ports. In Debian / Ubuntu this can be accomplished by adding the user to the 'dialout' group. Schedule the script to run every X minutes / hours using crontab.

4. DEFINITION OF VARIABLES

The config.yaml file should be placed in the same directory as the stadsverwarming.py script. The config file provides all settings required by the script. This paragraph will explain the purpose of these settings. To make it easier to configure this script, a demo config.yaml is supplied on GitHub.

main section

This section is used for the main configuration of the script.

  • serialport (required)

    The serial port used to contact the IR Schreib Lesekopf (or compatible). This usually corresponds to a Linux serial port (like /dev/ttyUSB1). If you experience that this changes after a reboot, please use a udev rule to make a static mapping. On systems running Windows it will probably work to use COM1 or the COM port which corresponds to the port which is used to connect to the IR Schreib Lesekopf.

  • destination (required)

    Can be 'mqtt', 'http' or 'screen'. Defines what to do with the data received from the meter. Http sends the readings directly to the Home Assistant RESTful API. MQTT needs an MQTT broker which can be subscribed to by Home Assistant or another home automation application which supports MQTT. Screen can be used for debugging or testing purposes as it just shows the meter readings to the screen. It does not need parameters set in any other section.

  • compare_previous_readings

    Can be True or False. On the first run (even when set to False) a text file called 'previous_readings.txt' will be created, containing the energy and volume reading. If set to True the new reading will be compared to the old reading. Because the meter can only count forwards, no new values lower than the previous one will be allowed. This feature is implemented because my meter sometimes gives wrong information back (not sure why). When selected, the script will also check if the difference between the new reading is not too big. To configure this the following options can be used.

  • energy_threshold (optional)

    This section is only required when compare_previous_readings is enabled. Enter how much GJ difference between the previous reading and current reading should be considered normal.

  • volume_threshold (optional):

    This section is only required when compare_previous_readings is enabled. Enter how much M3 difference between the previous reading and current reading should be considered normal.

mqtt section

This section is required if destination is set to mqtt

  • broker (required)

    Ip address or FQDN of MQTT broker. The script will use this broker to send the measurements values. Only a single MQTT topic will be used.

  • port (required)

    The port where the MQTT service is listening on. MQTT default is 1883, default when using ssl/tls is 8883.

  • username (optional)

    If authentication on the MQTT broker is required, please specify the username. If this setting removed from the configration, no authentication will be attempted. I recommend protecting MQTT with a username and a strong password.

  • password (optional)

    If authentication on the MQTT broker is required, please specify the password. This setting requires a username to be defined.

  • certificate (optional)

    Specify a certificate to verify the connection to the MQTT broker. Might be /etc/ssl/certs/ca_certificates.crt when the server certificate has been signed by a generally trusted authority. If this setting is removed from the configuration, plain text MQTT will be used. I recommend using ssl/tls.

  • tls_version (optional)

    Specify the tls version to be used. Choose one of the following:

    • SSLv23
    • TLS
    • TLSv1
    • TLSv1_1
    • TLSv1_2

    I recommend selecting TLSv1_2 which corresponds to TLS v1.2. This setting requires a certificate to be defined.

  • tls_insecure (optional)

    Set to true if you want to switch off checking the hostname in the used certificate. I recommend leaving this configured to 'false'. This setting requires a certificate to be defined.

  • topic: (required)

    The script will send the measurement values as JSON to this topic.

  • retain (required):

    Specify the retain flag for the message. It will be set as 'last known good' or retained on the broker.

Home Assistant configuration

As an example you can make a configuration item in Home Assistant's configuration.yaml. You need to define the connection to the MQTT broker if it does not already exist. It is also possible to define this connection in a separate yaml file and link it by using !include .

    mqtt:
      broker: 192.168.1.x
      port: 8883
      username: homeassistant
      password: password
      certificate: /etc/ssl/certs/ca_certificates.crt
      tls_version: '1.2'

Also you will need to define a few sensors to use with the stadsverwarming script. Those are situated on the 'sensors:' configuration item in the configuration.yaml. This may also be placed in a separate file linked by !include . An example of how to do this is:

    - platform: mqtt
      state_topic: home-assistant/stadsverwarming
      name: "Temperature in"
      unit_of_measurement: "°C"
      value_template: "{{ value_json.Temperature_in }}"
    - platform: mqtt
      state_topic: home-assistant/stadsverwarming
      name: "Temperature out"
      unit_of_measurement: "°C"
      value_template: "{{ value_json.Temperature_out }}"
    - platform: mqtt
      state_topic: home-assistant/stadsverwarming
      name: "Volume"
      unit_of_measurement: "M3"
      value_template: "{{ value_json.Volume }}"
    - platform: mqtt
      state_topic: home-assistant/stadsverwarming
      name: "Energy"
      unit_of_measurement: "GJ"
      value_template: "{{ value_json.Energy }}"

Tests

This script has been tested on Debian Stretch using the IR Schreib Lesekopf (infrared read write head) from Volkszaehler (https://wiki.volkszaehler.org/hardware/controllers/ir-schreib-lesekopf). The Home Assistant versions used to test were 0.62.1 and 0.67.0. The MQTT part has been tested with Mosquitto (1.4.15-0mosquitto3)

The script has been tested with the following destinations / settings:

  • http with password
  • http without password
  • https with password
  • mqtt with TLS1.2 and password
  • mqtt without encryption and without password