MOX-Compensation-SGP30

In this repository, we provide the data we have used to compensate sensitivity changes of duty-cycled MOX gas sensors with machine learning. Details about our work can be found in our paper:

@inproceedings{tug-eip2021sgp30, 
  author = {Gherman, Markus-Philipp and Cheng, Yun and Gomez, Andres and Saukh, Olga},
  title = {Compensating Altered Sensitivity of Duty-Cycled MOX Gas Sensors with Machine Learning},
  year = {2021},
}

Datasets

In the folder data, we provide 5 different datasets. Each dataset contains data from 3 SGP30 sensors running simultaneously. Device1 was operated continuously, device2 was operated on-demand with an on-time of 5 seconds and random off-times and device3 was duty-cycled with an on-time of 5 secons and a period of 5 minutes.

Name Duration [h] #samples [device1] #samples [device3] #samples [device2]
dataset_train_test 144 51485 1728 1700
dataset_test_04d 96 34325 1152 1099
dataset_test_18d 63 22768 764 780
dataset_test_22d 72 27133 911 949
dataset_test_53d 96 326164 1152 1944

Additionally, we have included plots visualizing each dataset, where we plot each sample from the continuous datasets and the last value of each sample from the duty-cycle and on-demand datasets.

Dataset Structure

The dataset csv files have the following header:

time,rel. Time,tVOC,CO2eq,Ethanol,H2,Temperature,Rel. Humidity

  • time describes the absolute time-stamp
  • rel. Time was used internally as a relative time-stamp
  • tVOC describes the tVOC measurement
  • CO2eq describes the CO2eq measurement
  • Ethanol describes the Ethanol measurement
  • H2 describes the H2 measurement
  • Temperature describes the temperature measurement
  • Rel. Humidity describes the relative humidity measurement

The samples from the datasets can be read as followed:

Continuous (device1) datasets:

Each sample is terminated with a row starting with an end identifier. The row before describes the measurement values. The measurement values are duplicated in the end row for convenience.

Duty-cycle (device3) and on-demand (device2) datasets:

Each sample is terminated with a row starting with an end identifier. The rows before describe the measurements taken during the on-time of the device with 36Hz. In these modes, there are no tVOC and no CO2eq measurements available. Temperature and relative humidity can be extracted from the end row.