Added a PR to the eufy-robovac repo.
Found that you have to force the IP. This wil fix the Error: find() timed out. Is the device powered on and the ID or IP correct?
Also giving a issueRefreshOnConnect will work with the statuses on startup of the Lib.

Next to that. I think that the memory issue comes from the on('data') event. the statuses are written to the variable. But when the vaccuum is moving it's overflowing and overwriting the complete list of the DPS values and only sending the location: Data from device: { dps: { '108': '[-307,2396,-8]' }, t: 1619003237 } instead of

  dps: {
    '102': 'Quiet',
    '104': 76,
    '105': 'MopHigh',
    '107': false,
    '108': '[-307,2396,-8]',
    '109': 10,
    '110': 0,
    '111': 43,
.....

Hope this helps. :)