Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathUnit.py
193 lines (149 loc) · 6.42 KB
/
Unit.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
# Python import
# User Import
# -----------------------------------------------------------
# Job : Unit Conversion
#
# Editor : aymhenry@gmail.com
# -
class Unit:
# Factor used to change other unit.
# Example DIST_Unit1_Unit2, factor to change from unit1 to unuit 2 : unit1 = DIST_Unit1_Unit2 * Unit2
# DIST : Distance
# TEMP : Temperature F1(T) = (T - 32.0)/1.8 !F to C
# ENRG : Energy
# COND : Conductivity (BTU/HR-FT-F)
DIST_INCH_CM = 2.54
DIST_INCH_MM = 25.4
DIST_FEET_INCH = 12
TEMP_F_COF1 = 32.0
TEMP_F_COF2 = 1.8
# 1 watt = 3.41442595 Btu (th)/hour
POWR_W_BTUH = 3.41442595 # 3.413
VOLU_FT_LITER = 28.317
# 1 watt/m K = 0.048174 Btu(th) /hr.inch Deg-F
COND_WattM_BtuThHrInchF = 0.048174
# 1 cm watt/square meter/K = 0.06938111789 Btu (th) inch/hour/square foot/DEG_F
COND_WATTCM_BTU_INCH = 0.069380
# 1 Btu (th) foot/hour/square foot/DEG_F = 1.729577206 watt/meter/K Conductivity
# 1 watt/meter/K = 1/1.729577206 Btu (th) foot/hour/square foot/DEG_F
COND_WATTM_BTU_FOOT = 1/1.729577206 # 1/1.7307
# -----------------------------------------------
@staticmethod
def WattM_BtuThHInchF(Watt):
return Watt * Unit.COND_WattM_BtuThHrInchF
@staticmethod
def BtuThHInchF_WattM(BtuH):
return BtuH / Unit.COND_WattM_BtuThHrInchF
# -----------------------------------------------
@staticmethod
def Watt_BtuH(Watt):
return Watt * Unit.POWR_W_BTUH
@staticmethod
def BtuH_Watt(BtuH):
return BtuH / Unit.POWR_W_BTUH
# -----------------------------------------------
@staticmethod
def f_c(temp_F):
return (temp_F - Unit.TEMP_F_COF1) / Unit.TEMP_F_COF2
@staticmethod
def c_f(temp_C):
return Unit.TEMP_F_COF2 * temp_C + Unit.TEMP_F_COF1
# -----------------------------------------------
@staticmethod
def ft3_liter(ft3):
return ft3 * Unit.VOLU_FT_LITER
@staticmethod
def liter_ft3(liter):
return liter / Unit.VOLU_FT_LITER
# -----------------------------------------------
# .......Distrance
@staticmethod
def feet_mm(dist_feet):
return dist_feet * Unit.DIST_INCH_MM * Unit.DIST_FEET_INCH
@staticmethod
def mm_feet(dist_mm):
return dist_mm / Unit.DIST_INCH_MM / Unit.DIST_FEET_INCH
# -----------------------------------------------
@staticmethod
def inch_mm(dist_inch):
return dist_inch * Unit.DIST_INCH_MM
@staticmethod
def mm_inch(dist_mm):
return dist_mm / Unit.DIST_INCH_MM
# -----------------------------------------------
@staticmethod
def inch_feet(dist_inch):
return dist_inch / Unit.DIST_FEET_INCH
@staticmethod
def feet_inch(dist_feet):
return dist_feet * Unit.DIST_FEET_INCH
# -----------------------------------------------
@staticmethod
def inch_cm(dist_inch):
return dist_inch * Unit.DIST_INCH_CM
@staticmethod
def cm_inch(dist_cm):
return dist_cm / Unit.DIST_INCH_CM
# -----------------------------------------------
@staticmethod
def cm_feet(dist_cm):
return dist_cm / Unit.DIST_INCH_CM / Unit.DIST_FEET_INCH
@staticmethod
def feet_cm(dist_feet):
return dist_feet * Unit.DIST_INCH_CM * Unit.DIST_FEET_INCH
# .......Cond
# 1 watt/meter/K = 6.938111789 Btu(th) inch/hour/square foot/DEG_F
# 1 cm watt/square meter/K = 0.06938111789 Btu(th) inch/hour/square foot/DEG_F
# -----------------------------------------------
@staticmethod
def CmWattM2K_BtuInchHrF2F(cond_watt):
# input : cm watt/square meter/K or(CM.W/m2-DEG_C)
# output: Btu(th) inch/hour/square foot/DEG_F or(BTU-INCH/HR-FT2-DEG F)
return cond_watt * Unit.COND_WATTCM_BTU_INCH
@staticmethod
def BtuInchHrF2F_CmWattM2K(cond_btu):
# input : Btu(th) inch/hour/square foot/DEG_F or(BTU-INCH/HR-FT2-DEG F)
# output: cm watt/square meter/K or or(CM.W/m2-DEG_C) or or(CM.W/m2-K)
return cond_btu / Unit.COND_WATTCM_BTU_INCH
# -----------------------------------------------
@staticmethod
def CmWattM2K_BtuHrFtF(cond_watt):
# input : cm watt/square meter/K or(CM.W/m2-DEG_C) CmWattF2K
# output:(BTU/HR-FT-DEG F) BtuHrFtF
# Btu(th) inch/hour/square foot/DEG_F /12 = Btu(th) /hour/ foot/DEG_F/12 or
# conductivity to resistivity example: resistivity = 1/ watt_btuInch(cond_watt)
# resistivity unit = hr foot DEG_F/ Btu(th).
# Unit.COND_WATTCM_BTU_INCH / Unit.DIST_FEET_INCH = 0.069380 / 12
return cond_watt * Unit.COND_WATTCM_BTU_INCH / Unit.DIST_FEET_INCH
@staticmethod
def BtuHrFtF_CmWattM2K(cond_btu):
# input: Btu(th) inch/hour/square foot/DEG_F /12 = Btu(th) /hour/ foot/DEG_F/12 or(BTU/HR-FT-DEG F)/12
# output : cm watt/square meter/K or(CM.W/m2-DEG_C)
#
# Unit.DIST_FEET_INCH / Unit.COND_WATTCM_BTU_INCH = 12/0.069380
return cond_btu * Unit.DIST_FEET_INCH / Unit.COND_WATTCM_BTU_INCH
# -----------------------------------------------
@staticmethod
def WattMK_BtuHrFtF(cond_watt):
# input : watt/meter/K or(W/m-DEG_C) WattMK
# output: Btu(th) /hour/foot/DEG_F or(BTU/HR-FT-DEG F) BtuHrFtF
return cond_watt * Unit.COND_WATTM_BTU_FOOT
@staticmethod
def BtuHrFtF_WattMK(cond_btu):
# input: Btu(th) /hour/foot/DEG_F or(BTU/HR-FT-DEG F)
# output : watt/meter/K or(W/m-DEG_C)
return cond_btu / Unit.COND_WATTM_BTU_FOOT
# -----------------------------------------------
@staticmethod
def WattMK_BtuHrInchF(cond_watt):
# input : watt/meter/K or(W/m-DEG_C) WattMK
# output: Btu(th) /hour/foot/DEG_F or(BTU/HR-IN-DEG F) BtuHrInchF
# Unit.COND_WATTM_BTU_FOOT/Unit.DIST_FEET_INCH = 0.04818133185627408
return cond_watt * Unit.COND_WATTM_BTU_FOOT/Unit.DIST_FEET_INCH
@staticmethod
def BtuHrInchF_WattMK(cond_btu):
# input: Btu(th) /hour/foot/DEG_F or(BTU/HR-IN-DEG F)
# output : watt/meter/K or(W/m-DEG_C)
# Unit.DIST_FEET_INCH / Unit.COND_WATTM_BTU_FOOT = 20.75492
return cond_btu * Unit.DIST_FEET_INCH / Unit.COND_WATTM_BTU_FOOT
# -----------------------------------------------