CGSchwarzMayo
Copy link

Add tags for DeIdentificationMethod and DeIdentificationMethodCodeSeuence, corresponding to the same-named DICOM tags. These record info on de-identification, including metadata and image content (e.g. de-facing or removing burned-in text)

…uence, corresponding to the same-named DICOM tags. These record info on de-identification, including metadata and image content (e.g. de-facing or removing burned-in text)
@CGSchwarzMayo
Copy link
Author

This addresses issue #1709

Copy link

codecov bot commented Apr 12, 2024

Codecov Report

All modified and coverable lines are covered by tests ✅

Project coverage is 87.93%. Comparing base (01025da) to head (9a32e88).

❗ Current head 9a32e88 differs from pull request most recent head 4fab2f4. Consider uploading reports for the commit 4fab2f4 to get more accurate results

Additional details and impacted files
@@           Coverage Diff           @@
##           master    #1772   +/-   ##
=======================================
  Coverage   87.92%   87.93%           
=======================================
  Files          16       16           
  Lines        1375     1351   -24     
=======================================
- Hits         1209     1188   -21     
+ Misses        166      163    -3     

☔ View full report in Codecov by Sentry.
📢 Have feedback on the report? Share it here.

Copy link
Collaborator

@effigies effigies left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Okay, to validate these, we will need to add them to sidecars.

https://github.com/bids-standard/bids-specification/blob/master/src/schema/rules/sidecars/mri.yaml

I would suggest a pair of new tables, such as:

DeidentificationMethod:
  selectors:
    - intersects([modality], ["mri", "pet"])
  fields:
    DeidentificationMethod: optional
    DeidentificationMethodCodeSequence:
      level: optional, but recommended if DeidentificationMethod is present

DeidentificationMethodRec:
  selectors:
    - intersects([modality], ["mri", "pet"])
    - sidecar.DeidentificationMethod
  fields:
    DeidentificationMethodCodeSequence: recommended

Then for rendering, these can then be added to the lists of tables for MRI data:

### Hardware information
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRIHardware") }}
Example for `ReceiveCoilActiveElements`:
For Siemens, coil channels are typically not activated/selected individually,
but rather in pre-defined selectable "groups" of individual channels,
and the list of the "groups" of elements that are active/selected in any
given scan populates the `Coil String` entry in Siemens' private DICOM fields
(for example, `HEA;HEP` for the Siemens standard 32 ch coil
when both the anterior and posterior groups are activated).
This is a flexible field that can be used as most appropriate for a given
vendor and coil to define the "active" coil elements.
Since individual scans can sometimes not have the intended coil elements selected,
it is preferable for this field to be populated directly from the DICOM
for each individual scan, so that it can be used as a mechanism for checking
that a given scan was collected with the intended coil elements selected.
### Institution information
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRIInstitutionInformation") }}
### Sequence Specifics
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRISequenceSpecifics") }}
### In- and Out-of-Plane Spatial Encoding
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table(["mri.MRISpatialEncoding", "mri.PhaseEncodingDirectionRec"]) }}
<sup>2</sup>Conveniently, for Siemens data, this value is easily obtained as
`1 / (BWPPPE * ReconMatrixPE)`, where BWPPPE is the
"BandwidthPerPixelPhaseEncode" in DICOM Tag 0019, 1028 and ReconMatrixPE is
the size of the actual reconstructed data in the phase direction (which is NOT
reflected in a single DICOM Tag for all possible aforementioned scan
manipulations). See
[Acquiring and using field maps - LCNI](https://lcni.uoregon.edu/wiki/acquiring-and-using-field-maps/)
and [TotalReadoutTime - dcm\_qa](https://github.com/neurolabusc/dcm_qa/tree/master/In/TotalReadoutTime).
<sup>3</sup>We use the time between the center of the first "effective" echo
and the center of the last "effective" echo, sometimes called the "FSL definition".
### Timing Parameters
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table(["mri.MRITimingParameters", "mri.SliceTimingMRI"]) }}
### RF & Contrast
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table(["mri.MRIFlipAngleLookLockerFalse", "mri.MRIRFandContrast" ]) }}
### Slice Acceleration
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRISliceAcceleration") }}
### Anatomical landmarks
Useful for multimodal co-registration with MEG, (S)EEG, TMS, and so on.
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRIAnatomicalLandmarks") }}
### Echo-Planar Imaging and *B<sub>0</sub>* mapping
Echo-Planar Imaging (EPI) schemes typically used in the acquisition of
diffusion and functional MRI may also be *intended for* estimating the
*B<sub>0</sub>* field nonuniformity inside the scanner (in other words,
*mapping the field*) without the acquisition of additional MRI schemes
such as gradient-recalled echo (GRE) sequences that are stored under the
`fmap/` directory of the BIDS structure.
The modality labels `dwi` (under `dwi/`), `bold` (under `func/`),
`asl` (under `perf/`), `sbref` (under `dwi/`, `func/` or `perf/`), and
any modality under `fmap/` are allowed to encode the MR protocol intent for
fieldmap estimation using the following metadata:
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRIEchoPlanarImagingAndB0Mapping") }}
#### Tissue description
<!-- This block generates a metadata table.
These tables are defined in
src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
src/schema/objects/metadata.yaml
A guide for using macros can be found at
https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.MRISample") }}

e.g.

### Deidentification information

<!-- This block generates a metadata table.
These tables are defined in
  src/schema/rules/sidecars
The definitions of the fields specified in these tables may be found in
  src/schema/objects/metadata.yaml
A guide for using macros can be found at
 https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_sidecar_table("mri.DeidentificationMethod") }}

Each object in the `DeidentificationMethodCodeSequence` array includes the following RECOMMENDED keys:

<!-- This block generates a table describing subfields within a metadata field.
The definitions of these fields can be found in
  src/schema/objects/metadata.yaml
and a guide for using macros can be found at
 https://github.com/bids-standard/bids-specification/blob/master/macros_doc.md
-->
{{ MACROS___make_subobject_table("metadata.DeidentificationMethodCodeSequence.items") }}

And we should do the same for PET.

src/schema/objects/metadata.yaml Outdated Show resolved Hide resolved
src/schema/objects/metadata.yaml Outdated Show resolved Hide resolved
@CGSchwarzMayo
Copy link
Author

I apologize for missing some pieces, and I think I understand, now. Thank you for your careful review and for helping me through this process. I will execute your suggestions and amend the PR with another commit.

@effigies
Copy link
Collaborator

No need to apologize! I appreciate the effort you're putting into this.

@CGSchwarzMayo
Copy link
Author

Chris,

I committed your suggested diffs as-is. For the tables and sidecars, I deviated a bit in calling both tags optional. My read of DICOM is that if PatientIdentityRemoved is TRUE (which is a tag we don't have in BIDS, and I don't think BIDS really needs it), then at least one of either DeidentificationMethod or DeidentificationCodeSequence is required. Without PatientIdentityRemoved, I would say neither is required, and both are optional. It's not that DeidentificationMethod is recommended if DeidentificationCodeSequence is present, but rather they are of equal status and people can use either. DeidentificationMethod is a single simple string, but there's a greater chance that some downstream software would replace rather than amend the string. DeidentificationCodeSequence better accounts for there being a series of de-identification steps and other software would more likely amend than overwrite it, but it's also a sequence tag and those are unpleasantly messy.

While I was copying from the MRI to the PET table, I noticed the "defacemask" block in the MRI but not PET. I copied this to the PET, since de-facing is also routinely applied to PET now.

I looked for CT-related files, but it appears that CT is not a part of BIDS currently? If CT is ever added, my recommendation is that these elements all be added to CT to match MRI and PET.

Thanks for your help and careful review!

@effigies
Copy link
Collaborator

For the tables and sidecars, I deviated a bit in calling both tags optional. My read of DICOM is that if PatientIdentityRemoved is TRUE (which is a tag we don't have in BIDS, and I don't think BIDS really needs it), then at least one of either DeidentificationMethod or DeidentificationCodeSequence is required. Without PatientIdentityRemoved, I would say neither is required, and both are optional.

Sounds good.

While I was copying from the MRI to the PET table, I noticed the "defacemask" block in the MRI but not PET. I copied this to the PET, since de-facing is also routinely applied to PET now.

Could you split that out into a separate PR? I think it will need some additional work to apply properly to PET, and I'd rather not complicate this PR more than necessary.

I looked for CT-related files, but it appears that CT is not a part of BIDS currently? If CT is ever added, my recommendation is that these elements all be added to CT to match MRI and PET.

Correct, and agreed!

Copy link
Collaborator

@effigies effigies left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

A few small suggestions. Also, in case you haven't seen it hiding in the review boxes (see image), here's the rendered specification, which will update a few minutes after you make pushes to this PR.

image

src/schema/rules/sidecars/pet.yaml Outdated Show resolved Hide resolved
@CGSchwarzMayo
Copy link
Author

Chris,
I attempted to make all the changes you suggested. The automated checks that failed appear to be related to parts of the code that I did not change in this branch, so unrelated to my changes. Thanks for your continuing reviews.
Chris

@effigies effigies changed the title [ENH][SCHEMA] Add tags for DeIdentificationMethod/CodeSequence [ENH] Add metadata fields for DeIdentificationMethod/CodeSequence for MRI and PET Apr 24, 2024
Copy link
Collaborator

@effigies effigies left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I'm happy with this from a schema and rendering perspective, and I believe this should be relatively simple to implement for DICOM converters.

I would appreciate if at least a couple representatives of converters could weigh in:

(I know you're all busy, please feel free to delegate.)

For those who would rather read spec than schema:

@CGSchwarzMayo
Copy link
Author

CGSchwarzMayo commented Apr 25, 2024

Thanks Chris (Markiewicz)!

I have a companion PR for dcm2niix at rordenlab/dcm2niix#813, but Chris (Rorden) hasn't commented on it yet. I had initially asked him to add the tags to dcm2niix's .json, and he said to get them added to bids-specification first, so that's how I arrived here.

I don't have any involvement with the other converters.

Thanks,
Chris (Schwarz)

type: string
description: |
An identifier of the version of the coding scheme if necessary to resolve ambiguity.
Corresponds to DICOM Tag 0008, 0103 `Coding Scheme Version`.
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I think this is complicated enough warranting addition to https://github.com/bids-standard/bids-examples if not as an example here in the BIDS spec text. Do we have some nice example DICOMs to check those fields out?

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I think if someone were creating these tags from scratch at the BIDS level, they would use DeidentificationMethod rather than DeidentificationMethodCodeSequence. The latter is more provided to allow direct translation by dcm->nii and dcm->bids software.

I'm attaching some nice example DICOM, as requested. This is MRI of a spaghetti squash (thanks @captainnova), and I've further de-identified it, so there's no PHI. I included the tags as if I had de-faced it, but it is a squash, so there was no face to de-face.

dcm_fruit_deidentified.zip

The relevant dcm tags look like this:

(0012, 0063) De-identification Method            LO: ['mri_reface 0.3.4', 'Per DICOM PS 3.15 AnnexE. Details in 0012,0064']
(0012, 0064)  De-identification Method Code Sequence   5 item(s) ---- 
   (0008, 0100) Code Value                          SH: '113102'
   (0008, 0102) Coding Scheme Designator            SH: 'DCM'
   (0008, 0103) Coding Scheme Version               SH: '01'
   (0008, 0104) Code Meaning                        LO: 'Clean Recognizable Visual Features Option'
   ---------
   (0008, 0100) Code Value                          SH: 'replace_recognizable'
   (0008, 0102) Coding Scheme Designator            SH: 'mri_reface'
   (0008, 0103) Coding Scheme Version               SH: '0.3.4'
   (0008, 0104) Code Meaning                        LO: 'Replace face, ears, and artifacts in air'
   ---------
   (0008, 0100) Code Value                          SH: '113100'
   (0008, 0102) Coding Scheme Designator            SH: 'DCM'
   (0008, 0104) Code Meaning                        LO: 'Basic Application Confidentiality Profile'
   ---------
   (0008, 0100) Code Value                          SH: '113107'
   (0008, 0102) Coding Scheme Designator            SH: 'DCM'
   (0008, 0104) Code Meaning                        LO: 'Retain Longitudinal Temporal Information Modified Dates Option'
   ---------
   (0008, 0100) Code Value                          SH: '113111'
   (0008, 0102) Coding Scheme Designator            SH: 'DCM'
   (0008, 0104) Code Meaning                        LO: 'Retain Safe Private Option'
   ---------

With rordenlab/dcm2niix#813, the relevant portion of json output is:

        "DeidentificationMethod": "mri_reface 0.3.4\\Per DICOM PS 3.15 AnnexE. Details in 0012,0064",
        "DeidentificationMethodCodeSequence": [ 
          { 
                "CodeValue": "113102",
                "CodingSchemeDesignator": "DCM",
                "CodingSchemeVersion": "01",
                "CodeMeaning": "Clean Recognizable Visual Features Option"
          },
          { 
                "CodeValue": "replace_recognizable",
                "CodingSchemeDesignator": "mri_reface",
                "CodingSchemeVersion": "0.3.4",
                "CodeMeaning": "Replace face, ears, and artifacts in air"
          },
          { 
                "CodeValue": "113100",
                "CodingSchemeDesignator": "DCM",
                "CodeMeaning": "Basic Application Confidentiality Profile"
          },
          { 
                "CodeValue": "113107",
                "CodingSchemeDesignator": "DCM",
                "CodeMeaning": "Retain Longitudinal Temporal Information Modified Dates Option"
          },
          { 
                "CodeValue": "113111",
                "CodingSchemeDesignator": "DCM",
                "CodeMeaning": "Retain Safe Private Option"
          }
        ],