Generate an openhab text configuration based on an ETS project File. Despite all things and items, the sitemap for basicui is generated. The semantic model is supported.
- edit
config.json
- the default locations for the output files match directly, if you create a
openhab
directory and mount the/etc/openhab
there. (under linux use e.g.sshfs pi@[myIP]:/etc/openhab openhab
)
- the default locations for the output files match directly, if you create a
- run
python3 knxproject_to_openhab.py
Within the configuration, there is a field drop_words
. There you can define words which should not be used in labels. E.g. lights have already a bulb symbol. So the word light is not needed in the description. However, if the description would be empty after cleanup, the words are not dropped! (e.g. you have a light right
and a light left
-> bulb symbols with the words right
and left
. If you have only one light, the name will not be shortend as it is already short ;) )
IP Gateway: will match by config
- devices - gateway - hardware_name and gets IPv4 Address from description field
there are some addons based on the description field of the GA in ETS. Multiple options are seperated by a semicolon.
- add
influx
to automatically save the values to influxDB. - add
debug
to add a visibility tag to a element. Use itemextended_view
to change visibility. - scene mappings: see below
- add
location
to add the location to the first two layers of group addresses. Divide multiple by,
- add
semantic
to overwrite the default entries. (e.g. if a switch is controlling a projector: semantic=Projector). Possible options. Divide multiple by,
- add
icon
to set the icon. e.g.icon=projector
- add
ignore
to competely disable the import for that GA
(e.g. semantic=Pump;icon=pump;debug;influx
)
DPT Types DPTTypes Numbers are now member of UoM
- Temperature based on Datatype
- Humidity based on Datatype
- Window Contact based on Datatype 1.019
- Electrical work (wh) based on Datatype
- Power (W) based on Datatype
- Curent based on Datatype
- Lux based on Datatype
- Day/Night based on Datatype 1.024
- Alarm based on Datatype 1.005
- Speed m/s based on Datatype
- Timedifference based on Datatype 13.100
- Scene based on Datatype. Add for example
63='Aus', 62='Automatik', 1='Kochen', 2='Beamer', 3='Allgemein'
to description in ETS to generate automatic mapping. - ppm based on Datatype
- Percent based on Datatype
- Volume based on Datatype
- String based on Datatype
- Rollershutter based on Name
- Switch - based on Datatype. Looking for a status GA with the same name and suffix configured in config.json/"switch"/"status_suffix". Default: "Status"
- Example: GAs "Light right" + "Light right Status"
- Lights, powerplugs and audio devices can be detected by names configured at config.json -> defines -> switch - change_metadata -> "poweroutlet_name" / "speaker_name" / "light_name". The configured name has to be part of the GA Name.
- Dimmer - based on suffix in config.json/"dimmer"/"suffix_absolut" (default: "Dimmen absolut"). Also searching for: "status_suffix" (default "Status Dimmwert") Dropping all GA suffixes within config.json/"dimmer"/"drop".
- Example: GAs "Light Dimmen absolut" + "Light Status Dimmwert"