Package to help decode smart power meter data stream of IEC 62056-21 Mode D P1 or DLMS/Cosem HDLC frames used by MBUS (Meter Bus). The package can both help reading frames of meter data and/or decoding them.
The package has special support for DLMS formats used by Aidon, Kaifa and Kamstrup smart meteres (HAN) in Norway (See https://www.nek.no/info-ams-han-utviklere/) and Sweden. The Swedish P1 format format is also supported.
SmartMeterMessagePayloadProtocol can be used to read smart meter P1 date readout (ascii) or MBUS HDLC (binary) frames asynchronous. The content of each mdssage (no headers and control characters) is passed as bytes to a Queue. Headers are checked and checksum validated, and only content from non empty frames with expected length (only DLMS) and checksum is passed to the queue.
SmartMeterMessageProtocol can be used to read smart meter P1 data readout (ascii) or MBUS HDLC frames asynchronous. The complete message is sent to a Queue as an instance of as subclass of MeterReaderBase. Frames are not validated. This class is a more low level alternative to SmartMeterMessagePayloadProtocol. This type has to be used to get the meter type from P1 readouts as this is part of the message "header".
Both SmartMeterMessagePayloadProtocol and SmartMeterMessageProtocol is a Python asyncio protocol. Protocols support different types of transports like network and serial.
It is recommended to use provided ConnectionManager and connection factories to read the data stream.
Pass a factory for the selected protocol (SmartMeterMessagePayloadProtocol or SmartMeterMessageProtocol) to a utility function of your selected transport (e.g., EventLoop.create_connection() for TCP/IP or serial_asyncio.create_serial_connection() for serial).
Serial example:
transport, protocol = await serial_asyncio.create_serial_connection(loop, lambda: SmartMeterMessagePayloadProtocol(queue, [ModeDReader]), url = "/dev/tty01")
Serial example:
transport, protocol = await serial_asyncio.create_serial_connection(loop, lambda: SmartMeterMessagePayloadProtocol(queue, [ModeDReader]), url = "/dev/tty01")
Multiple factories are provided to create a protocol as an alternative to using selected transports create function as above. Use serial_connection_factory for serial and tcp_connection_factory for TCP/IP.
Factory module | SmartMeterMessageProtocol | SmartMeterMessagePayloadProtocol |
---|---|---|
serial_connection_factory | create_serial_message_payload_connection() | create_serial_message_connection() |
tcp_connection_factory | create_tcp_message_connection() | create_tcp_message_payload_connection() |
Example of creating a SmartMeterMessagePayloadProtocol serial connection on device /dev/ttyUSB0:
queue = Queue()
loop = asyncio.get_event_loop()
transport, protocol = await create_serial_frame_content_connection(queue, loop, None, url="/dev/ttyUSB0", baudrate=2400, parity=N)
Example of creating a SmartMeterMessageProtocol protocol TCP/IP connection to host 192.168.1.1 on port 1234:
queue = Queue()
loop = asyncio.get_event_loop()
transport, protocol = await create_tcp_frame_connection(queue, loop, None, "192.168.1.1", 1234)
See reader_async.py for a complete example.
ConnectionManager maintain connection and reconnect if connection is lost. A back-off retry strategy is used when reconnecting, and a simple circuit breaker is used for lost connection.
queue = Queue()
loop = asyncio.get_event_loop()
connection_manager = ConnectionManager(lambda: create_serial_message_connection(queue, loop, None, url="/dev/ttyUSB0", baudrate=2400, parity=N))
await connection_manager.connect_loop()
See reader_async.py for a complete example.
dlde.ModeDReader can be used to read readout by readout from bytes. Call read() to read readouts as more bytes become available. The function takes bytes as an argument and returns a list of DataReadout (the list can be empty). The function can receive incomplete readout in the buffer input and add incomplete data to an internal buffer. The buffer is schrinked when complete readout are found and returned. You should check if returned readouts are valid with readout.is_valid before using them.
hdlc.HdlcFrameReader can be used to read frame by frame from bytes. Call read() to read frames as more bytes become available. The function takes bytes as an argument and returns a list of HdlcFrame (the list can be empty). The function can receive incomplete frames in the buffer input and add incomplete data to an internal buffer. The buffer is schrinked when complete frames are found and returned. You should check if returned frames are valid with frame.is_valid before using them.
P1 readout and MBUS frames using the norwegian or swedish DMLS AMS format can be parsed into meter specific objects or decoded into a common dictionary. Modules exists for P1 (generic format), Aidon, Kaifa and Kamstrup meters, but the easiest is to use autodecoder.AutoDecode to automatically detect meter type and decode the frame into a dictionary. The dictionay content is as far as possible common between meters. Possible dictionary keys kan be found as constants in obis_map.py.
Example:
decoder = AutoDecoder()
frame = bytes.fromhex("e6e700" "0f" "40000000" "00" "0101" "020309060100010700ff060000011802020f00161b")
decoded = decoder.decode_frame_content(frame)