Description
Very occasionally, if you stop and re-start the RFID test too quickly, CrossMgrImpinj gets into a wedged state where it stops communicating with CrossMgr. (Communication with the tag reader continues normally.) The frozen connection does not time out, even after CrossMgr is closed. If you restart CrossMgrImpinj, everything works normally.

Steps to reproduce the behavior
Start CrossMgrImpinj and CrossMgr.
Perform an RFID test.
Repeatedly stop and restart the RFID test until CrossMjrImpinj's right hand window shows a frozen handshake with CrossMgr.
Note that nothing you can do from the CrossMgr side restores communication with CrossMgrImpinj.

Expected behavior
CrossMgrImpinj should be able to determine the connection is frozen, close and re-attempt to establish the connection to CrossMgr.
Failing that, CrossMgr should not allow you to re-start the RFID test immediately after stopping one.

Screenshots
See video capture here: https://youtu.be/ATKShKZLIzc I manage to get it to freeze at 32 seconds in.

Desktop (please complete the following information):
Windows 11
CrossMgrImpinj 3.0.16
CrossMgr 3.1.05

Additional context
This occurred at last weekend's BHPC event, we suspect due to an accidental double-click on the "Stop RFID Test" button. Due to Murphy's Law, as everyone who understands the system was in the race, an unskilled volunteer started the race in CrossMgr, and did not realise there was a problem for about 20 minutes.

(We were running the previous version of CrossMgr/CrossMgrImpinj, but I've upgraded and confirmed the bug persists in the current release.)

@esitarski
Copy link
Owner

esitarski commented Sep 27, 2022 via email

@kimble4
Copy link
Contributor Author

kimble4 commented Sep 27, 2022

I've done a quck test (without a tag reader connected) using CrossMgrImpinj_3_0_16-20220927155532.exe and it seems to think it's still connected to CrossMgr even after CrossMgr is closed, which doesn't seem right.

I'll test more thoroughly when I've got time to dig the tag reader out and set it up.

@kimble4
Copy link
Contributor Author

kimble4 commented Sep 29, 2022

Okay, tried CrossMgrImpinj 3.0.16-20220927155532
with the tag reader connected. Again, repeated restarting of the RIFD test causes CrossMgrImpinj to freeze while the connection is initialised, which then does not time out and reconnect:

https://www.youtube.com/watch?v=qjPKpJApzLo

In the absence of this freeze condition, it correctly times out the connection if CrossMgr goes away, but I note that it only seems to notice the connection is dead when a tag read comes in:

https://www.youtube.com/watch?v=W1kF2lZf7Ug

(If no tag reads arrive, as when I posted the comment above, it appears that the connection never times out.)

Could this be a threading issue, perhaps?

@esitarski
Copy link
Owner

esitarski commented Sep 29, 2022 via email

@kimble4
Copy link
Contributor Author

kimble4 commented Sep 30, 2022

This seems a lot better, when the socket closes during the handshake:

CrossMgr Connection succeeded!
Sending identifier "BHPC-Timing-11584"...
CrossMgr error: [WinError 10054] An existing connection was forcibly closed by the remote host.
Trying to connect to CrossMgr at 127.0.0.1:53135 as "BHPC-Timing-11584"...

And:

CrossMgr Connection succeeded!
Sending identifier "BHPC-Timing-11584"...
Waiting for GT (get time) command from CrossMgr...
CrossMgr error: [WinError 10054] An existing connection was forcibly closed by the remote host.
Trying to connect to CrossMgr at 127.0.0.1:53135 as "BHPC-Timing-11584"...

Whereas a graceful shutdown gets:

CrossMgr error: [WinError 10053] An established connection was aborted by the software in your host machine.

rather than the 10054 error above, for reasons that probably make sense to Windows (I assume depending on whether the socket closure handshake completes properly), so it would appear that it was an unhandled exception.

I've been clicking the start/stop button like a maniac for about 15 minutes now, successfully interrupting the handshake several times, and haven't had it freeze at all, so that looks like it's fixed.

The lack of a heartbeat is mostly a UI issue at this point, as it will reconnect when tag reads arrive. I suppose that might be more important if you're running CrossMgrImpinj on a different machine to CrossMgr (for multiple start/finish lines or whatever). I work on the principle that you can usually trust localhost to work :)