Question about light source #37
Comments
hi Chaitanya, MCX/MMC gives you the Green's function. That means the intensity of the source is assumed to be 1 (unitary). However, fluence is linearly proportional to the intensity of the source. so if your source have a different intensity, you simply multiply the solution by your source intensity. let me know if this answers your question. |
Dr. Fang, Thank you for your reply. I wanted to know if it is possible to initiate photon packets from the source at different time points and not as an instantaneous pulse at time t=0. Also, would I be able to simulate an optical coherence tomography acquisition with this software? If not, could you point me to possible alternatives? Thank you, |
that is also support if you utilizes the properties of the Green's function (i.e. TPSF if in the time-domain). If you have an arbitrary waveform for the source, all you need to do is to convolve that source waveform with the TPSF at every location derived from MCX/MMC. |
Dr. Fang,
Thank you for this software. I'd like to know if there is a way to configure the photon fluence rate of the source?
Thanks,
Chaitanya
The text was updated successfully, but these errors were encountered: