Battery screen is missing info (v1.11) #329

Closed
HarmOtten opened this issue Mar 5, 2016 · 6 comments
Closed

Battery screen is missing info (v1.11) #329

HarmOtten opened this issue Mar 5, 2016 · 6 comments

Comments

@HarmOtten
Copy link
Contributor

  1. On this screen the SOH is not showing anymore. On other screens it still does.
  2. The scale of the Cell Voltages is max 4 Volt. Since the voltage are above 4 Volt, it would be better to change the scale to max 5 Volt. Or even better, from 2 or 3 to 5 Volt.
@fesch
Copy link
Owner

fesch commented Mar 6, 2016

The field was commented out in the Fields class :-(

I've reactivated it.

@yoh-there
Copy link
Collaborator

Oops, I am sorry, my bad. If not done already, please do update the spreadsheet too (Y in column "used in CanZE") so it will be re-exported once we generate those tables again. It is a recipe for introducing regressions ;-)

@Pixel91630
Copy link

Hello,
On the PlayStore, the last version is 1.11, Feb. 15th.
The SOH is still not showing.
How can I get the lats modified version ?
Thanks in advance.

@yoh-there
Copy link
Collaborator

We have no release date planned, but it is fixed in the current source code and will be included in the next release, when it will come out. Further, see http://canze.fisch.lu/downloads/ (about "bleeding edge")

@Pixel91630
Copy link

Thanks for your help.
I found the SOH in an other screen of the application.

@MAlfare
Copy link

MAlfare commented May 16, 2016

Hi
I waited for for this release so long, but was told today by Jeroen, that it was done already on 11th of April.
Have installed: Version 1.12 // Build: 2016.04.11 @ 07:56.-
But in "Battery" screen, the bottom left field "Cell Voltages (V)" is still totally empty.

Is it only me?
Regards
Manfred