32 changes: 26 additions & 6 deletions gestionatr/input/messages/B70.py
Original file line number Diff line number Diff line change
Expand Up @@ -1312,6 +1312,7 @@ def get_lectures_info(self):
res = []
if not hasattr(self, 'meters'):
self.meters = [self]
factor_ultima_lectura = False
for meter in self.meters:
fecha_desde = meter.feclecant
fecha_actual = meter.feclecact
Expand All @@ -1335,7 +1336,7 @@ def get_lectures_info(self):
excesocaudal = float(meter.excesocaudal)
temperatura_gas = float(meter.temp)
pressio_atmosferica = float(meter.presatm)

consum_kwh_facturat = float(meter.consumokwh)
for numerador in meter.listanumeradores:
lectura_desde_m3 = float(numerador.lectant)
lectura_actual_m3 = float(numerador.lecact)
Expand Down Expand Up @@ -1373,18 +1374,37 @@ def get_lectures_info(self):
'temperatura_gas': float(temperatura_gas),
'pressio_atmosferica': float(pressio_atmosferica),
}
# Si el consum que calculem amb el factor_k i el pcs no dona el consum informat en el tag consumokwh

# Si el consum que calculem amb el factor_k i el pcs no dona el consum calculat amb el factor de conversio
# pero si fem servir el factor de conversio informat per la distri si que dona, modfiquem el factor_k perque
# el factor de conversio calculat sigui igual al informat i aixi el consum també quadri.
# TODO
# Revisant un cas concret, sembla que realment ens falta aplicar la zeta, per aixo no quadra.
# Normalment es 1 pero pot no ser-ho. Aixó es una mandanga per no ahver de treballar amb la zeta.
consum_calculat = round(vals['consum_m3'] * vals['pcs'] * vals['factor_k'], 3)
consum_facturat = round(vals['consum'], 3)
if consum_facturat != consum_calculat:
consum_calculat_sefons_fomrula = round(vals['consum_m3'] * vals['pcs'] * vals['factor_k'], 3)
consum_calculat_segons_factor = round(vals['consum'], 3)
if consum_calculat_segons_factor != consum_calculat_sefons_fomrula:
consum_calculat = round(vals['consum_m3'] * meter.factorconver, 3)
if consum_facturat == consum_calculat:
if consum_calculat_segons_factor == consum_calculat:
vals['factor_k'] = meter.factorconver / vals['pcs']

# Unaltre cas concret de ***
# Hi ha distris que tot i tindre lectures diaries no apliquen el factor de conversio registart en
# cada dia, sino que paliquen a totes les lectures de tots els dies el factor de conversio de la
# ultima lectura
# Per tant: si el consum facturat per la distri no coincideix amb el consum calculat, ero aplicant
# el faactor de conversio del ultim dia siq ue aplica, recalculem el factor k perque quadri tot.
if consum_kwh_facturat != consum_calculat_segons_factor:
if not factor_ultima_lectura and self.meters[-1].factorconver:
factor_ultima_lectura = float(self.meters[-1].factorconver)
if factor_ultima_lectura:
consum_calculat_segons_factor_ultim = round(vals['consum_m3'] * factor_ultima_lectura, 3)
if consum_calculat_segons_factor_ultim == consum_kwh_facturat:
vals['factor_k'] = consum_kwh_facturat / (vals['consum_m3'] * vals['pcs'])
vals['consum'] = consum_kwh_facturat
elif round(consum_calculat_segons_factor_ultim, 0) == consum_kwh_facturat:
vals['factor_k'] = consum_kwh_facturat / (vals['consum_m3'] * vals['pcs'])
vals['consum'] = consum_kwh_facturat
res.append(vals)
return res