Skip to content

Commit

Permalink
docs: Update etc/telegraf.conf and etc/telegraf_windows.conf
Browse files Browse the repository at this point in the history
  • Loading branch information
Tiger Bot committed Jun 22, 2022
1 parent 336ae2f commit 3ac85fc
Show file tree
Hide file tree
Showing 2 changed files with 208 additions and 186 deletions.
197 changes: 104 additions & 93 deletions etc/telegraf.conf
Original file line number Diff line number Diff line change
Expand Up @@ -21,98 +21,96 @@
## Environment variables can be used as tags, and throughout the config file
# user = "$USER"


# Configuration for telegraf agent
[agent]
## Default data collection interval for all inputs
interval = "10s"
## Rounds collection interval to 'interval'
## ie, if interval="10s" then always collect on :00, :10, :20, etc.
round_interval = true

## Telegraf will send metrics to outputs in batches of at most
## metric_batch_size metrics.
## This controls the size of writes that Telegraf sends to output plugins.
metric_batch_size = 1000

## Maximum number of unwritten metrics per output. Increasing this value
## allows for longer periods of output downtime without dropping metrics at the
## cost of higher maximum memory usage.
metric_buffer_limit = 10000

## Collection jitter is used to jitter the collection by a random amount.
## Each plugin will sleep for a random time within jitter before collecting.
## This can be used to avoid many plugins querying things like sysfs at the
## same time, which can have a measurable effect on the system.
collection_jitter = "0s"

## Collection offset is used to shift the collection by the given amount.
## This can be be used to avoid many plugins querying constraint devices
## at the same time by manually scheduling them in time.
# collection_offset = "0s"

## Default flushing interval for all outputs. Maximum flush_interval will be
## flush_interval + flush_jitter
flush_interval = "10s"
## Jitter the flush interval by a random amount. This is primarily to avoid
## large write spikes for users running a large number of telegraf instances.
## ie, a jitter of 5s and interval 10s means flushes will happen every 10-15s
flush_jitter = "0s"

## Collected metrics are rounded to the precision specified. Precision is
## specified as an interval with an integer + unit (e.g. 0s, 10ms, 2us, 4s).
## Valid time units are "ns", "us" (or "µs"), "ms", "s".
##
## By default or when set to "0s", precision will be set to the same
## timestamp order as the collection interval, with the maximum being 1s:
## ie, when interval = "10s", precision will be "1s"
## when interval = "250ms", precision will be "1ms"
##
## Precision will NOT be used for service inputs. It is up to each individual
## service input to set the timestamp at the appropriate precision.
precision = "0s"

## Log at debug level.
# debug = false
## Log only error level messages.
# quiet = false

## Log target controls the destination for logs and can be one of "file",
## "stderr" or, on Windows, "eventlog". When set to "file", the output file
## is determined by the "logfile" setting.
# logtarget = "file"

## Name of the file to be logged to when using the "file" logtarget. If set to
## the empty string then logs are written to stderr.
# logfile = ""

## The logfile will be rotated after the time interval specified. When set
## to 0 no time based rotation is performed. Logs are rotated only when
## written to, if there is no log activity rotation may be delayed.
# logfile_rotation_interval = "0h"

## The logfile will be rotated when it becomes larger than the specified
## size. When set to 0 no size based rotation is performed.
# logfile_rotation_max_size = "0MB"

## Maximum number of rotated archives to keep, any older logs are deleted.
## If set to -1, no archives are removed.
# logfile_rotation_max_archives = 5

## Pick a timezone to use when logging or type 'local' for local time.
## Example: America/Chicago
# log_with_timezone = ""

## Override default hostname, if empty use os.Hostname()
hostname = ""
## If set to true, do no set the "host" tag in the telegraf agent.
omit_hostname = false

## Method of translating SNMP objects. Can be "netsnmp" which
## translates by calling external programs snmptranslate and snmptable,
## or "gosmi" which translates using the built-in gosmi library.
# Configuration for telegraf agent
[agent]
## Default data collection interval for all inputs
interval = "10s"
## Rounds collection interval to 'interval'
## ie, if interval="10s" then always collect on :00, :10, :20, etc.
round_interval = true

## Telegraf will send metrics to outputs in batches of at most
## metric_batch_size metrics.
## This controls the size of writes that Telegraf sends to output plugins.
metric_batch_size = 1000

## Maximum number of unwritten metrics per output. Increasing this value
## allows for longer periods of output downtime without dropping metrics at the
## cost of higher maximum memory usage.
metric_buffer_limit = 10000

## Collection jitter is used to jitter the collection by a random amount.
## Each plugin will sleep for a random time within jitter before collecting.
## This can be used to avoid many plugins querying things like sysfs at the
## same time, which can have a measurable effect on the system.
collection_jitter = "0s"

## Collection offset is used to shift the collection by the given amount.
## This can be be used to avoid many plugins querying constraint devices
## at the same time by manually scheduling them in time.
# collection_offset = "0s"

## Default flushing interval for all outputs. Maximum flush_interval will be
## flush_interval + flush_jitter
flush_interval = "10s"
## Jitter the flush interval by a random amount. This is primarily to avoid
## large write spikes for users running a large number of telegraf instances.
## ie, a jitter of 5s and interval 10s means flushes will happen every 10-15s
flush_jitter = "0s"

## Collected metrics are rounded to the precision specified. Precision is
## specified as an interval with an integer + unit (e.g. 0s, 10ms, 2us, 4s).
## Valid time units are "ns", "us" (or "µs"), "ms", "s".
##
## By default or when set to "0s", precision will be set to the same
## timestamp order as the collection interval, with the maximum being 1s:
## ie, when interval = "10s", precision will be "1s"
## when interval = "250ms", precision will be "1ms"
##
## Precision will NOT be used for service inputs. It is up to each individual
## service input to set the timestamp at the appropriate precision.
precision = "0s"

## Log at debug level.
# debug = false
## Log only error level messages.
# quiet = false

## Log target controls the destination for logs and can be one of "file",
## "stderr" or, on Windows, "eventlog". When set to "file", the output file
## is determined by the "logfile" setting.
# logtarget = "file"

## Name of the file to be logged to when using the "file" logtarget. If set to
## the empty string then logs are written to stderr.
# logfile = ""

## The logfile will be rotated after the time interval specified. When set
## to 0 no time based rotation is performed. Logs are rotated only when
## written to, if there is no log activity rotation may be delayed.
# logfile_rotation_interval = "0h"

## The logfile will be rotated when it becomes larger than the specified
## size. When set to 0 no size based rotation is performed.
# logfile_rotation_max_size = "0MB"

## Maximum number of rotated archives to keep, any older logs are deleted.
## If set to -1, no archives are removed.
# logfile_rotation_max_archives = 5

## Pick a timezone to use when logging or type 'local' for local time.
## Example: America/Chicago
# log_with_timezone = ""

## Override default hostname, if empty use os.Hostname()
hostname = ""
## If set to true, do no set the "host" tag in the telegraf agent.
omit_hostname = false

## Method of translating SNMP objects. Can be "netsnmp" which
## translates by calling external programs snmptranslate and snmptable,
## or "gosmi" which translates using the built-in gosmi library.
# snmp_translator = "netsnmp"

###############################################################################
# OUTPUT PLUGINS #
###############################################################################
Expand Down Expand Up @@ -586,7 +584,8 @@
# ## Write URL override; useful for debugging.
# # url = "https://app.datadoghq.com/api/v1/series"
#
# ## Set http_proxy (telegraf uses the system wide proxy settings if it isn't set)
# ## Set http_proxy
# # use_system_proxy = false
# # http_proxy_url = "http://localhost:8888"
#
# ## Override the default (none) compression used to send data.
Expand Down Expand Up @@ -2307,6 +2306,10 @@
# # socks5_username = "alice"
# # socks5_password = "pass123"
#
# ## Optional HTTP proxy to use
# # use_system_proxy = false
# # http_proxy_url = "http://localhost:8888"
#
# ## Data format to output.
# ## Each data format has it's own unique set of configuration options, read
# ## more about them here:
Expand Down Expand Up @@ -3656,7 +3659,8 @@
# ## ex: endpoint_url = "http://localhost:8000"
# # endpoint_url = ""
#
# ## Set http_proxy (telegraf uses the system wide proxy settings if it's is not set)
# ## Set http_proxy
# # use_system_proxy = false
# # http_proxy_url = "http://localhost:8888"
#
# # The minimum period for Cloudwatch metrics is 1 minute (60s). However not all
Expand Down Expand Up @@ -7326,6 +7330,10 @@
# # tls_cert = "/etc/telegraf/cert.pem"
# # tls_key = "/etc/telegraf/key.pem"
# # tls_server_name = "myhost.example.org"
#
# ## Set the proxy URL
# # use_proxy = true
# # proxy_url = "http://localhost:8888"


# # Gathers Metrics From a Dell EMC XtremIO Storage Array's V3 API
Expand Down Expand Up @@ -9135,6 +9143,9 @@
# ## specify server password
# # password = "s#cr@t%"
#
# ## specify username for ACL auth (Redis 6.0+)
# # username = "default"
#
# ## Optional TLS Config
# # tls_ca = "/etc/telegraf/ca.pem"
# # tls_cert = "/etc/telegraf/cert.pem"
Expand Down

0 comments on commit 3ac85fc

Please sign in to comment.