Skip to content

lemanjo/pyupway

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

61 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

pyupway

Simple utility to read values from either MyUpway or MyUplink cloud service. Currently works only with one system at a time.

When using MyUplink, first visit https://dev.myuplink.com/apps and create new app in order to get the API credentials. Note that History data is not supported with MyUplink service.

Supported devices

Currently pyupway has been tested on following units

  • Jäspi MCU40
  • Jäspi Tehowatti AIR
  • Jäspi Basic Split 8/12 kW
  • Nibe Metro-air 330
  • Nibe F470

Installation

Install using pip

pip install pyupway

Usage

Basic usage is to import MyUpway, MyUpwayConfig and DataService from pyupway. Then in Config specify which DataService are you using.

MyUpway

Initialize MyUpwayConfig with proper settings and use it to initialize MyUpway itself. You can obtain heat pump id from the MyUpway UI URL

https://www.myupway.com/System/<heatpumpId>/Status/Overview
from pyupway import MyUpway, MyUpwayConfig, Variable, DataService

config = MyUpwayConfig(dataservice=DataService.MYUPWAY, username="<username>", password="<password>", heatpump_id=123456)

myupway = MyUpway(config)

print(myupway.get_current_values([Variable.HIGH_PRESSURE_SENSOR]))
print(myupway.get_history_values(Variable.EXTERNAL_FLOW_TEMP, startDate=datetime(2023,6,1,0,0,0), stopDate=datetime(2023,6,4,0,0,0)))

MyUplink

Get Client ID and Client Secret from MyUplink dev site: https://dev.myuplink.com/apps

Initialize MyUpwayConfig with proper settings and use it to initialize MyUpway itself.

https://www.myupway.com/System/<heatpumpId>/Status/Overview
from pyupway import MyUpway, MyUpwayConfig, Variable, DataService

config = MyUpwayConfig(dataservice=DataService.MYUPLINK, client_id="<client_id>", client_secret="<client_secret>")

myupway = MyUpway(config)

print(myupway.get_current_values([Variable.HIGH_PRESSURE_SENSOR]))

Data classes

Results are returned in defined dataclasses

VariableValue

from pyupway import VariableValue
Field Type
Id int
Name str
Enumerator Variable
Value int | float | str | bool | None
Unit str | None
EnumValue str | None
UpdatedAt datetime | None

VariableHistoryValue

from pyupway import VariableHistoryValue
Field Type
Value int | float | str | bool | None
Unit str | None
Date datetime

Data Services

Value Meaning
MYUPWAY Download data from MyUpway service
MYUPLINK Download data from MyUplink service

Variables available

Enum Name Variable ID History Data
AVG_OUTDOOR_TEMP 40067 yes
HOT_WATER_CHARGING 40014 TBT
HOT_WATER_TOP 40013 TBT
INDOOR_UNIT_OUTDOOR_TEMP 40004 yes
CURRENT_BE1 40083 yes
CURRENT_BE2 40081 yes
CURRENT_BE3 40079 yes
DEGREE_MINUTES 43005 yes
EXTERNAL_ADJUSTMENT 43161 no
FLOOR_DRYING_FUNCTION 47276 no
CALCULATED_FLOW_TEMP 43009 yes
EXTERNAL_FLOW_TEMP 40071 yes
EXTERNAL_RETURN_TEMP 40152 yes
HEAT_MEDIUM_FLOW 40008 TBT
HEAT_RETURN_TEMP 40012 TBT
ROOM_TEMPERATURE 40033 yes
ADDITION_BLOCKED 10033 no
ADDITION_MAX_STEP 47613 no
ADDITION_STATUS 43091 yes
ADDITION_FUSE_SIZE 47214 no
ADDITION_TIME_FACTOR 43081 TBT
ADDITION_ELECTRICAL_ADDITION_POWER 43084 TBT
ADDITION_SET_MAX_ELECTRICAL_ADD 47212 TBT
ADDITION_TEMPERATURE 40121 TBT
ENERGY_COOLING_COMPRESSOR_ONLY 44302 TBT
ENERGY_HEATING_COMPRESSOR_ONLY 44308 TBT
ENERGY_HEATING_INT_ADD_INCL 44300 TBT
ENERGY_HOTWATER_COMPRESSOR_ONLY 44306 TBT
ENERGY_HW_INCL_INT_ADD 44298 TBT
ENERGY_POOL_COMPRESSOR_ONLY 44304 TBT
ENERGY_FLOW 40072 TBT
INVERTER_STATUS 50096 ??
AUX1 47411 no
AUX2 47410 no
AUX3 47409 no
AUX4 47408 no
AUX5 47407 no
AUX6 48366 no
X7 47412 no
COUNTRY 48745 no
DEFROSTING 44703 no
CHARGE_PUMP_SPEED 44396 yes
OUTDOOR_UNIT_OUTDOOR_TEMP 44362 yes
COMPRESSOR_BLOCKED 10014 no
COMPRESSOR_STARTS 44069 yes
COMPRESSOR_PROTECTION_MODE 44702 no
CONDENSER_OUT 44058 yes
EVAPORATOR 44363 yes
HOT_GAS 44059 yes
LIQUID_LINE 44060 yes
RETURN_TEMP 44055 yes
SUCTION_GAS 44061 yes
HIGH_PRESSURE_SENSOR 44699 yes
HIGH_PRESSURE_SENSOR_EB101 41163 ??
LOW_PRESSURE_SENSOR 44700 yes
COMPRESSOR_OPERATING_TIME 44071 yes
COMPRESSOR_OPERATING_TIME_HOT_WATER 44073 yes
COMPRESSOR_RUN_TIME_COOLING 40737 yes
CURRENT_COMPRESSOR_FREQUENCY 44701 yes
REQUESTED_COMPRESSOR_FREQUENCY 40782 no
VERSION 44014 no
SMART_PRICE_STATUS 44908 ??
SMART_PRICE_VALUE 10069 ??
SMART_PRICE_FACTOR 44896 ??
SUPPLY_LINE 40047 ??
RETURN_LINE 40048 ??
OIL_TEMPERATURE_EP15_BT29 40145 ??
OIL_TEMPERATURE_BT29 40146 ??
MYUPLINK_DEGREE_MINUTES 40940 ??
SLAVE_EB101 44032 ??
STATUS_COMPRESSOR_EB101 44064 ??
CHARGE_PUMP_EB101_GP12 49996 ??
CURRENT_HOT_WATER_MODE 43109 ??
HOT_WATER_CHARGE_SET_POINT_VALUE 43115 ??
PUMP_HEATING_MEDIUM 49992 ??
INT_ELEC_ADD_HEAT 49993 ??
PRIORITY 49994 ??
PUMP_HEATING_MEDIUM_2 49995 ??
TEMPORARY_LUX 50004 ??
COMFORT_MODE 47041 ??
COMPRESSOR_EVAPORATOR_TEMP 40020
COMPRESSOR_TEMP 40023
ADDITION_IMMERSION_HEATER_TEMP 40024
AIR_EXHAUST_TEMP 40025
AIR_EXTRACT_TEMP 40026
SMART_PRICE_MODE 41929
DESIRED_HUMIDITY_1 42770
DEFROSTING_TIME 43066
FAN_MODE 43108
COMPRESSOR_STATUS 43427
SMART_PRICE_POOL_OFFSET 44898
SMART_PRICE_COOLING_OFFSET 44899
OPERATING_MODE 47137
DESIRED_HUMIDITY_2 49633
AIR_INCREASED_VENTILATION 50005

Functions

get_current_values

Returns the current values for selected variables. Provide variables as a list of Variable enums.

Example

myupway.get_current_values([Variable.HIGH_PRESSURE_SENSOR, Variable.AVG_OUTDOOR_TEMP])

get_history_values

Returns the historical values for specified timerange. NOT IMPLEMENTED FOR MYUPLINK!

Example

myupway.get_history_values(Variable.EXTERNAL_FLOW_TEMP, startDate=datetime(2023,6,1,0,0,0), stopDate=datetime(2023,6,4,0,0,0))

Contributors

Thank you for contributing to the project!

  • lobstaj
  • sulate