It builds on #4040
There is only one new commit here (the latest one); it might be better to cherry-pick - but this combined PR ensures that there are no unit-errors in the library.
This commit changes a start-value and actually changes the simulation results for the example as follows.
Simulating Modelica.Electrical.Machines.Examples.ControlledDCDrives.SpeedControlledDCPM we get:
The blue line indicates that previously the inverter started with a current of 120A and then quickly settled at 0A, now it starts at 0A. The start-value was VMax - which doesn't make sense for a current; I believe it was copied from the voltage-controller-component.