Zabbix-related passages

A set of some zabbix-related passages

zabbix-agent

If you have configured SELinux in enforcing mode then you might have problem with systemctl start zabbix-agentd. The problem is that SELinux policy does not allow to set rlimit for zabbix-agentd. To solve this problem you need to build and install SELinux module by running

checkmodule -M -m -o zabbix-agent.mod zabbix-agent.te
semodule_package -o zabbix-agent.pp -m zabbix-agent.mod
semodule -i zabbix-agent.pp

systemctl-monitor

A set of files that enables Zabbix to monitor systemd services.

Installation

Copy contents of zabbix\_agentd.d folder to your /etc/zabbix/zabbix\_agentd.d folder. Restart zabbix agent.

Avialable keys

Key Description
systemd.service.status[service] Return status of service. Available statuses are active, inactive or unknown

SELinux

If you have configured SELinux in enforcing mode then you might have problem with this module (i.e. module status is unknown for running module or you start to receiving error messages instead of real status) This is because the SELinux policy that ships with RedHat/CentOS does not explicitly allow the Zabbix agent to communicate with D-Bus. So you need to build and install SELinux module by running

checkmodule -M -m -o zabbix-systemctl.mod zabbix-systemctl.te
semodule_package -o zabbix-systemctl.pp -m zabbix-systemctl.mod
semodule -i zabbix-systemctl.pp

APC UPSD

A set of files that enables Zabbix to monitor UPS connected via apcupsd.

Installation

Copy contents of zabbix\_agentd.d folder to your /etc/zabbix/zabbix\_agentd.d folder. Restart zabbix agent. Import APC_UPSD_Linux.xml into your zabbix server.

Avialable keys

Key Description
apcupsd.status Return status of APC UPS. One of the following: CAL TRIM BOOST ONLINE ONBATT OVERLOAD LOWBATT REPLACEBATT NOBATT SLAVE SLAVEDOWN COMLOST SHUTTING
apcupsd.name UPS name from configuration file for dumb upses or eprom for smart
apcupsd.model UPS model from ups information
apcupsd.version apcupsd version information
apcupsd.linev UPS Current input line voltage
apcupsd.load Percentage of UPS load capacity used as estimated by UPS
apcupsd.load Percentage of UPS load capacity used as estimated by UPS
apcupsd.timeleft Remaining runtime left on battery as estimated by the UPS
apcupsd.batt.charge Current battery capacity charge percentage
apcupsd.batt.V Current battery charge voltage
apcupsd.batt.nominal Nominal battery voltage

Template triggers

Template provide a set of triggers

Description Severinity Event
UPS initiated system shutdown Disaster apcuspd.status=='SHUTTING'
Low estimation on battarey High apcupsd.status=='ONBATT' and (apcupsd.batt.charge<20 or apcupsd.timeleft<3)
Lost connection with UPS High apcupsd.status='COMLOST'
UPS on battary Average apcupsd.status='ONBATT'

synology-ups

Template file that enables monitoring ups connected to Synology NASes.

Installation

Import synology_5_ups.xml into your zabbix server.

Avialable keys

Key Description
syno.ups.battary.charge[*] UPS battary charge
syno.ups.battary.chargelow[*] Low battary charge level from ups driver settings
syno.ups.battary.chargewarning[*] Warning battary charge level from ups driver settings
syno.ups.voltage.current[*] Current UPS voltage
syno.ups.voltage.nominal[*] Nominal UPS voltage
syno.ups.line.voltage.in[*] UPS line in voltage
syno.ups.line.voltage.out[*] UPS line out voltage
syno.ups.load[*] UPS load
syno.ups.timeleft[*] UPS time left on battary
syno.ups.status UPS status
syno.ups.model UPS model
syno.ups.version UPS driver version

Template macros

Name Value
UPS_TIME_LEFT 180

Template triggers

Template provide a set of triggers

Description Severinity Event
Empty battary High syno.ups.battary.charge[*]==syno.ups.battary.chargelow[*]
Almost no time left on battary High syno.ups.timeleft[*]<${UPS_TIME_LEFT}
Low battary Average syno.ups.battary.charge[*]==syno.ups.battary.chargewarning[*]
Power loss or ups problem Warning syno.ups.battary.status[*].str(OL)==0