You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
https://github.com/njfaria/SolPipLog/blob/master/docs/mqttvalues.md
change to BYPASS you probably are mentioning changing to solar or grid ? solpiplog/pip/status/set uti for example changes to grid
payloads are uti (grid ) sbu ( solar->battery->grid ) sol ( only solar )
some inverter do have autonl and eco as payloads
as for charging : solpiplog/pip/charge/set 0 changes to charge from grid
payloads 0 grid first 1 solar first ( no solar, starts to charge from grid ) 2 solar and grid ( not all inverters support this mode ) 3 solar only
solpiplog/pip/status/set uti for example changes to grid
How can i change fom Line "UTI" mode in Battery "SBU" mode? The other way it works fom SBU to UTI.
With Dalylog it works perfekt, but when i send it via MQTT it´s not taking the change!!!
But i would like to have Dalylog switch on Cell Voltage instead of SOC!
I have a Effekta AX-M2 3000.
HI Nuno,
your app it is wonderfull!!
i have 2 questions:
it is possible to start and stop the charging by MQTT?
it is possible to move to BYPASS mode by MQTT?
The text was updated successfully, but these errors were encountered: