HI Nuno,
your app it is wonderfull!!
i have 2 questions:

it is possible to start and stop the charging by MQTT?
it is possible to move to BYPASS mode by MQTT?

@njfaria
Copy link
Owner

njfaria commented Feb 10, 2024

https://github.com/njfaria/SolPipLog/blob/master/docs/mqttvalues.md
change to BYPASS you probably are mentioning changing to solar or grid ?
solpiplog/pip/status/set uti for example changes to grid
payloads are
uti (grid )
sbu ( solar->battery->grid )
sol ( only solar )
some inverter do have aut onl and eco as payloads
as for charging :
solpiplog/pip/charge/set 0 changes to charge from grid
payloads
0 grid first
1 solar first ( no solar, starts to charge from grid )
2 solar and grid ( not all inverters support this mode )
3 solar only

@kxn25
Copy link

kxn25 commented Mar 13, 2024

solpiplog/pip/status/set uti for example changes to grid

How can i change fom Line "UTI" mode in Battery "SBU" mode? The other way it works fom SBU to UTI.
With Dalylog it works perfekt, but when i send it via MQTT it´s not taking the change!!!
But i would like to have Dalylog switch on Cell Voltage instead of SOC!
I have a Effekta AX-M2 3000.