Command line utility for controlling Edimax plugs and cameras remotely through Edimax cloud service.
Sends commands and receives data from Edimax WiFi plugs and IP cameras using Edimax cloud service. Using EdiManager does not require being in the same network as the device nor configuring router port forwarding. Edimax plugs and cameras maintain connection to the cloud servers using undocummented protocol. EdiManager uses this protocol to control Edimax devices. Device is identified by Device ID (MAC address on a sticker). Access is authenticated with password.
EdiManager.exe DeviceId [Command] [Options]
DeviceId : Device Identifier, typically MAC address printed on sticker
Command : Commmand executed on device. If no command is provided, default
'probe' command will be used. EdiPlug commands:
on Switch on EdiPlug device
off Switch off EdiPlug device
toggle Toggle EdiPlug
pluginfo Output device info
getschedule Get schedule
power Get current power consumption
history Get power consumption history
Edimax IP camera commands:
image [fn] Get camera snapshot and save to jpg file with
name fn. If fn is not specified the
default name name will be used:
<DeviceId>_<DateTime>.jpg
web [port] Setup HTTP tunnel to access camera web
interface through local TCP port. If no port
is specified default 9999 port will be used
and web interface will be available at
http://localhost:9999
Commands applicable for any device:
probe Perform UDP probing only (checks if the device
is online)
Options:
-p, --password=VALUE Password for Edimax device. If password is not
provided user will be prompted to enter password
-v, --verbose Show more status messages. More -v means more
messages
-c, --cleartext Show messages exchanged with cloud in clear text
format
-x, --hexadecimal Show messages exchanged with Edimax cloud as raw
hexadecimal data
-t, --tcptimeout=VALUE Timeout for receiving TCP data from Edimax cloud [
ms]. Default is 20000
-u, --udptimeout=VALUE Timeout for receiving UDP data from Edimax cloud [
ms]. Default is 10000
-r, --tcpretries=VALUE Number of retries after TCP connection breaks.
Default is 10
-R, --udpretries=VALUE Number of retries after UDP connection breaks.
Default is 10
-i, --interval=VALUE Time interval between retrying connections [ms].
Default is 500
-e, --endpoint=VALUE Cloud UDP endpoint address used for initiating
connection to Edimax cloud. Default endpoint is
www.myedimax.com:8766
-h, --help Show this message and exit
Edimanager works with EdiPlugs SP1101W and SP2101W and cameras IC-3116W,
IC-3140W, IC-7001W but should work with other Edimax camera models as well.
Switching EdiPlug example:
EdiManager.exe 74DA38XXXXXX toggle -p 1234
Downloading camera snapshot example:
EdiManager.exe 74DA38XXXXXX image -p 1234 -m snapshot.jpg
- Works with Mono
- Hints form here used for deobfuscation code