Notifications
You must be signed in to change notification settings - Fork 2
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
KeyError: 'Receive Level' #2
Comments
Hi. Telling from the pixels (please upload your screenshot with a better resolution next time) your webinterfaces' header line is "Received Level" instead of "Receive Level". Probably the output has changed between the firmware versions. |
well I see... I guess QAM256 uppercase and MHz/Hz (Because of the metric system? :-D) Can you provide a screenshot of your cm connectionstatus? thank you! |
|
Your output is missing all codeword columns. Are you sure you're logged in to your tc4400's web interface as admin user? Another hint that makes me believe you're not logged in is that the config file is "hidden". |
you're right! but I was logged in as admin, maybe some caching issue. Nevermind, here we go:
|
Thanks. The current master should work with your firmware. |
confirmed. Thank you! |
Hi, changed from epc3212 to tc-4400 but I can't get your script running.
TC-4000:
Software Version: | 70.12.42-190604
Linux Version: | 3.14.28-Prod_18.1
/check_tc4400.py -u admin -p asdfghswdg -H 192.168.100.1
http://192.168.100.1/cmconnectionstatus.html works with this credentials.
What I'm doing wrong? please advice :-)
Thanks!
The text was updated successfully, but these errors were encountered: