-
Notifications
You must be signed in to change notification settings - Fork 205
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Too low humidity value compared to stock version and calibration result. Maximum humidity offset is only 12.7%. #163
Comments
LYWSD03MMC B1.9 uses SHT4x sensors: Always after flashing custom FW, the humidity value instantly decreases by 5.0% and begins to meet the of other sensors from other manufacturers. I will correct work with SHT4x in the new version - v4.5.
For this, open source codes are given. Correct as you wish. |
Thanks! I have now flashed most of my B1.9 thermometers with ATC_V35.bin. Seems that it works and now humidity value is same as with in stock firmware. Also values has been balanced after yesterday and they are very close to same humidity values that AirThings Wave Plus shows. I have also few LYWSD03MMC B1.4 with Sensor SHTC3 (also flashed to v3.5). They all show about 5 RH% lower values than B1.9. Is this sensor related or SW issue? There is workaround for humidity rounding, if I set Humidity offset=0.5 it will do rounding correctly LCD and advertisement when 0 digits used for humidity. This workaround does not work for temperature with 1 digit as Temperature offset=0.05 is not allowed. |
LYWSD03MMC B1.4 uses SHTV3 sensor. There is no documentation for it, but the commands is close to SHTC3. |
can you tell me where did you get the 1.9? I cant tell the difference on shops selleing them. |
I just had 10 pcs new LYWSD03MMC B1.9 thermometers. All of those have very similar humidity and temperature values in same placement with stock firmware. I flashed most of those sensors one by one to with latest firmware version 3.4. Always after flashing humidity value was decreased instantly by 11-12%. This is only concerning humidity, I do not see any relevant change in temperature value after firmware update.
I have had now all 10 thermometers in Sodium Chloride calibration box about >12 hours and thermometers with stock firmware shows 71-72% that is very close. All thermometers with pvvx firmware shows about 60%. Correct value for calibration should be 75.4%. Meaning that stock firmware is only 3-4% too low compared to calibration result (after 12h, I will still wait for >24h for final result), but pvvx firmware shows about 15% too low humidity value. I am using this procedure for humidity calibration:
https://www.vernier.com/til/4337
https://www.youtube.com/watch?v=aeLPRZQTA4w
I could use humidity offset to calibrate sensors but firmware config does now allow to set bigger values than 12.7%. If bigger value is given it will be set as 12.7%.
Also temperature and humidity values are not rounded in LCD or in advertisement (using Atc1441 because less digits). If temperature shown in Telink flasher is 23.87 it shows 23.8 in LCD and advertisement. Value 23.87 should be rounded to 23.9.
The text was updated successfully, but these errors were encountered: