RTS/CTS and contention window #39
Comments
Christina, Thanks for asking. There is no concept of RTS/CTS on the chipsets you mention. Neither one has a serial interface. Both have an MII interface. The QCA7000 has a serial interface that supports UART and can be set up to observer RTS/CTS protocol, if desired. Before we go too much further on this, are we sure about the chipset model numbers? |
Dear Charlie, Thank you very much for the quick reply. As far as I know QCA7000 is HomePlug GreenPhy. I do not have such kind of devices. Basically, I am a researcher and I am studying the MAC protocol of high data-rate devices, so I would like to modify some parameters such as the contention window, but I know that the firmware is encrypted. I would also like to test the network with the RTS/CTS mechanism which is specified by the IEEE 1901 standard, but I guess it is not possible if this concept does not exist. Concerning the chipset model numbers, this is what the command int6k -a returns, so I guess they are correct. Thank you for your help. |
The QCA7000 is different from other Qualcomm PLC chipsets. It is a On Thu, Nov 20, 2014 at 7:37 AM, christinavl notifications@github.com
|
I am studying the MAC layer of high data-rate PLC (HomePlug AV-AV2). I have managed to find some configurations (that is, some values for the contention windows and the deferral counters, which are parameters of the MAC layer) that boost the performance of the MAC. Thus, I would like to modify these parameters on the PLC chips to test some metrics such as throughput. I guess that the values for the contention windows and the deferral counters can be found and modified via the firmware. However, this firmware is encrypted, so no tests can be run with modified parameters. The only thing I could find is the .pib file, but I am not sure I could use this file to modify such parameters. It would be useful to know if these parameters can be modified somehow. Thanks and regards, Christina |
Hi Christina, The sorts of parameters you are talking about cannot be modified via the On Mon, Nov 24, 2014 at 7:39 AM, christinavl notifications@github.com
|
Hi Christina, I will be closing this issue soon, if that is OK with you. |
Yes, sure. Thanks. |
Hello,
I would like to enable the RTS/CTS mechanism on either chips INT6300 or AR7420.
I would also like to modify the contention window of the MAC protocol.
Do you know if I could modify the above with the open-plc-utils?
Thank you very much in advance!
Best,
Christina