Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

iCubGenova11 - Left thumb distal reads 90 degrees when fully open #1593

Closed
xEnVrE opened this issue Jul 6, 2023 · 7 comments
Closed

iCubGenova11 - Left thumb distal reads 90 degrees when fully open #1593

xEnVrE opened this issue Jul 6, 2023 · 7 comments
Assignees
Labels
iCubGenova11 S/N:050 iCub2.7 S/N:050

Comments

@xEnVrE
Copy link

xEnVrE commented Jul 6, 2023

Device name 🤖

iCubGenova11

Request/Failure description

When considering #1575, it was noticed that once the calibration is completed the left thumb distal is reading ~ 90 deegres when the joint is fully open - which is of course wrong.

Detailed context

A picture showing the weird configuration:

image

Additional context

No response

How does it affect you?

No response

@AntonioConsilvio
Copy link
Contributor

Hi @xEnVrE, yesterday I found the cable of one of the left thumb hall sensors damaged, and therefore to be replaced.

cc @sgiraz

@xEnVrE
Copy link
Author

xEnVrE commented Jul 20, 2023

Thanks, we can decide together the proper moment for fixing it.

@xEnVrE
Copy link
Author

xEnVrE commented Aug 1, 2023

Hi @sgiraz @AntonioConsilvio can I ask if there is any update on the schedule of this activity?

Thank you

@sgiraz
Copy link
Contributor

sgiraz commented Aug 2, 2023

Hi @xEnVrE,

As agreed, we scheduled the activity for tomorrow afternoon.

cc @AntonioConsilvio @GiacomoVassallo13

@AntonioConsilvio
Copy link
Contributor

Hi @xEnVrE, with the help of @Gandoo, today we replaced the cable RMFC_T_HS5, that connect the hall sensor HS5 to the MAIS board, and we have also replaced the hall sensor HS5.

Now the hall sensor read properly, but the finger need to be recalibrated, so tomorrow morning I will recalibrate the thumb distal.

cc @sgiraz @Fabrizio69

@xEnVrE
Copy link
Author

xEnVrE commented Aug 3, 2023

Thanks for the fix @AntonioConsilvio @Gandoo

@AntonioConsilvio
Copy link
Contributor

Hi @xEnVrE, I recalibrated and tested the distal joint of the left thumb.

Now the joint is working properly.

Remember to update the robots-configuration files:

cc @sgiraz

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
iCubGenova11 S/N:050 iCub2.7 S/N:050
Projects
Status: Done
Development

No branches or pull requests