PinIdea ASIC X11 Miner DRX(varyag) OS Image 170414
This release for drx:
Warning: MAC address will be changed if you just upgrade the device(miner) from older version of operating system image. Then it will be fixed, unless re-install(flash) operating system image.
Reference: HOW TO INSTALLING OPERATING SYSTEM IMAGES
https://www.raspberrypi.org/documentation/installation/installing-images/
One file for DHCP and One file for Static IP
Default Static IP : 192.168.1.200
User Manual
Dear Customers,
Pinidea would like to extend our humble gratitude for your purchase of the Drx!
Below is some brief descriptions of Drx hardware and software settings.
Hardware Description:
Drx contains 3-4 tablet boards, each of which is powered by a PCI-E power interface, and the main control board is powered by its onboard PCI-E power connector. All interfaces are 12V input. Drx's total power consumption is 750W. Each computing board power consumption is 170W, input 12V voltage and current is about 14A, the input interface for the PCI-E 6pin or 8pin (Figure 1: 6pin insert 8pin interface diagram). Powering the Drx using a server power supply requires a wall power supply of at least 800W.
Before supplying the Drx, you need to visually inspect the Drx, observe the appearance and the calculation board, and if any damage or abnormality is found, please contact us promptly to cause further damage.Plug each of the 12V PCI-E power supply board and the main control board 12V PCI-E power supply, and the main control of the network cable, check the various connectors are reliable connection can be set after the power.
During Drx operation, try to increase the distance between the Drx and the power supply, keep enough heat dissipation, Drx's temperature is higher than the set temperature limit will enter the protection mode and stop the calculation.
Software setup instructions:
- Drx factory network settings are two, namely Dhcp and Static, the machine will have a label on the package that the machine uses the network type, Static mode, the default IP address is 192.168.1.200.
- Login Drx software management interface, in the browser, enter http://ip (ip to replace the Drx IP, Static mode IP is 192.168.1.200) to open the management interface, the default password is admin.
- Set the pool, in the interface of the Pool Configuration, the current Drx default to provide three pools, each pool to set the Pool url (please do not add stratum+tcp:// this prefix, it will lead to Drx can not connect to the pool), Pool worker, Pool password, the details of each item, please refer to the requirements of the pool settings, click Save & Restart, wait Drx save the settings and restart the mining program.
- The Dashboard page shows the working status of the current Drx, and the ASIC status page shows the operating status of each chip.
- The Network Configuration page provides login password changes and network settings changes.
- The Update page provides an OTA upgrade and a local upgrade package upgrade.
- The Asis Frequent, Fan Speed, and cgminer related control parameter settings are available on the Pool Configuration page.
Troubleshooting:
- You can not log in to the background management interface.
In ensuring that the network cable has been properly connected to the case, check Drx's network port led lights are flashing.
Please check the Drx what kind of network settings to make sure ip is correct. - Drx have no mining speed.
Check the pool settings are correct, note do not enter the pool URL with stratum+tcp://prefix. - Forget the password.
Use the Drx recovery button to restore all settings(include password, network setting and pool setting) to default and generate new macaddr. - Drx buzzer alarm.
When Drx's cooling fan does not work, Drx stops working through the buzzer to emit an alarm sound.
Appendix 1