Infinitude

Docker image Build Status Docker Hub documentation

Documentation and information on protocol(s) available on the Wiki. Please contribute!

Infinitude is an alternative web service for Carrier Infinity Touch and compatible thermostats.

Infinitude allows direct web-based control of

  • Temperature setpoints
  • Schedules
  • Dealer information

As well as providing an open RESTish API

Infinitude can also optionally monitor the Carrier/Bryant RS485(ABCD) bus to obtain higher resolution access to values within your thermostat, air handler, heat pump, and other devices. Infinitude provides a serial monitor which keeps track of the current state of registers on the serial bus, and highlights changing bytes to aid in protocol analysis. Serial data can be monitored via an attached serial port or via a networked serial bridge.

RS485 stream monitoring example video:

Real time RS485 monitoring

Infinitude does not control thermostats via the RS485 bus in the default build at this time. RS485 communication is optional, and read only.

Serial-based control of touch thermostats is possible and has been demonstrated by writing to thermostat table 0x40 via Infinitude's CarBus library, but is experimental at this time.

Serial-based control of some older non-touch thermostats is provided by the Infinitive project

Docker - Recommended

Prebuilt Docker containers are available for multiple architectures on DockerHub, or you can build a container manually with the included Dockerfile. Special thanks go to @scyto for instrumental contributions to the Infinitude containers in general, and multiarch builds in particular.

Infinitude configuration parameters can be passed through environment variables into the container. Support is included for:

Variable Description
APP_SECRET Cookie signature string. Matters to almost nobody
PASS_REQS Minimum amount of time to wait(in seconds) between requests to Carrier/Bryant servers. 0 means never.
MODE production(default) or development(more logging)
SERIAL_TTY optional rs485 device string eg /dev/ttyUSB0
SERIAL_SOCKET optional tcp/rs485 bridge string eg 192.168.1.42:23
LOGLEVEL optional minimum severity of log messages to print
SCAN_THERMOSTAT truthy values on systems with serial connectivity cause Infinitude to continuously scan each Thermostat table

the published container can be run as

docker run --rm -v $PWD/state:/infinitude/state -p 3000:3000 nebulous/infinitude

with additional config items as ENV vars

docker run --rm -v $PWD/state:/infinitude/state \
-e APP_SECRET='YOUR_SECRET_HERE' \
-e PASS_REQS='1020' \
-e MODE='Production' \
-p 3000:3000 \
nebulous/infinitude

or via the included docker-compose file. docker-compose up

Manual installation Requirements

The easiest way to run Infinitude is by running a published Docker image, but if you'd like to install manually, these are the basic requirements

Software
  • Some flavor of UNIX. Both Linux and OSX are known to work and some have even used Strawberry Perl in Windows.
  • Perl with the following modules
    • Mojolicious
    • DateTime
    • IO::Termios optional for RS485 serial monitoring
    • Path::Tiny
    • Try::Tiny
    • JSON
Dependency Installation
  • a cpanfile is provided which lists Infinitude's minimum dependencies.
  • use your distribution's packaging system, your favorite cpan installer, or sudo cpanm --installdeps . to install
Raspbian-specific

Many users opt to run Infinitude on a Raspberry Pi. This is also most easily accomplished using a Docker image, but More specific manual installation instructions are available on the wiki

Hardware

Basic hardware capable of running docker or a unix/posix system. This could be a desktop machine, many people use a Raspberry Pi, or any embedded device with sufficient memory and storage. The author runs Infinitude in a Docker container on an Atomic PI, but has also used a Pandaboard and first ran it on the very limited Pogoplug v4 hardware, which at the time(2014) cost less than $10 USD and sat on top of the air handler and allowed for a USB RS485 dongle to interface with it.

See a list of hardware others have used.

Usage / Thermostat configuration

  • Set your proxy server/port in the advanced wireless settings on the thermostat to point to your infinitude host/port.
  • Edit the $conf section of the infinitude file to set your optional RS485 serial tty device.
  • Start Infinitude. This traffic is not encrypted, so only run on a trusted network.

Infinitude is a Mojolicious application, so the simplest way to run it from source is via:

./infinitude daemon

which starts a server in development mode on port 3000.

Or to listen on port 80:

./infinitude daemon -l http://:80

See ./infinitude --help for additional options

With any luck, Carrier will allow the owners of these devices and data direct access rather than this ridiculous work around. If you have one of these thermostats, tell Carrier you'd like direct network access to your thermostat, or at the very least, access to a public API!

See Also

About

Open control of Carrier/Bryant thermostats

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Perl 31.8%
  • HTML 27.9%
  • JavaScript 21.4%
  • C 15.0%
  • CSS 1.5%
  • Shell 1.0%
  • Other 1.4%