iio: sx9310: Fix semtech,avg-pos-strength setting when > 16
Browse files Browse the repository at this point in the history
This DT property can be 0, 16, and then 64, but not 32. The math here
doesn't recognize this slight bump in the power of 2 numbers and
translates a DT property of 64 into the register value '3' when it
really should be '2'. Fix it by subtracting one more if the number being
translated is larger than 31. Also use clamp() because we're here.

Cc: Daniel Campello <campello@chromium.org>
Cc: Lars-Peter Clausen <lars@metafoo.de>
Cc: Peter Meerwald-Stadler <pmeerw@pmeerw.net>
Cc: Douglas Anderson <dianders@chromium.org>
Cc: Gwendal Grignou <gwendal@chromium.org>
Cc: Evan Green <evgreen@chromium.org>
Signed-off-by: Stephen Boyd <swboyd@chromium.org>
Reviewed-by: Douglas Anderson <dianders@chromium.org>
Link: https://lore.kernel.org/r/20201202200252.986230-1-swboyd@chromium.org
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
  • Loading branch information
bebarino authored and jic23 committed Jan 14, 2021
1 parent 40c48fb commit b8653af
Showing 1 changed file with 2 additions and 1 deletion.
3 changes: 2 additions & 1 deletion drivers/iio/proximity/sx9310.c
Original file line number Diff line number Diff line change
Expand Up @@ -1305,7 +1305,8 @@ sx9310_get_default_reg(struct sx9310_data *data, int i,
if (ret)
break;

pos = min(max(ilog2(pos), 3), 10) - 3;
/* Powers of 2, except for a gap between 16 and 64 */
pos = clamp(ilog2(pos), 3, 11) - (pos >= 32 ? 4 : 3);
reg_def->def &= ~SX9310_REG_PROX_CTRL7_AVGPOSFILT_MASK;
reg_def->def |= FIELD_PREP(SX9310_REG_PROX_CTRL7_AVGPOSFILT_MASK,
pos);
Expand Down