Skip to content

Commit

Permalink
Merge pull request #4 from nurikk/patch-1
Browse files Browse the repository at this point in the history
Update README.md
  • Loading branch information
xyzroe authored Aug 9, 2021
2 parents 6255791 + 7994aea commit db6995d
Showing 1 changed file with 16 additions and 12 deletions.
28 changes: 16 additions & 12 deletions README.md
Original file line number Diff line number Diff line change
@@ -1,23 +1,27 @@
# Zintercom
# Zintercom

## How to compile
Follow this article https://zigdevwiki.github.io/Begin/IAR_install/

##### Zigbee Intercom Automator
This device is designed to control the matrix intercom using Zigbee.

Using zigbee2mqtt you can:
1. Receive notification when the intercom rings. (also support **direct bind**)
1. Receive a notification when the intercom rings. (also support **direct bind**)
2. Mute the sound on the intercom handset.
3. Automatically or manually open the door or hang up when the intercom rings.

There are 4 work modes:
1. `Never` - ordinary work mode, use handset to control
2. `Once` - one time open door when intercom rings
1. `Never` - ordinary work mode, use a handset to control
2. `Once` - one-time open door when intercom rings
3. `Always` - open door when intercom rings
4. `Drop` - hangs up all intercom rings, right after start
4. `Drop` - hangs up all intercom rings, right after the start

You can change the operating mode uisng z2m or by short press the button. (< 1000ms)
You can change the operating mode using z2m or by short press the button. (< 1000ms)
After pressing the button, the LED will flash at 4 Hz.
The number of flashes indicates the current operating mode.

You can control sound mode using z2m or by long press the button. (1000ms < X < 5000ms)
You can control sound mode using z2m or by long-press the button. (1000ms < X < 5000ms)
After pressing the button, the LED will flash at 1.5 Hz.
One flash - OFF, two flashes - ON.

Expand All @@ -33,7 +37,7 @@ Just plug by swapping.

#### 2
The problem of cross-calls to other apartments:
it was revealed that the intercom circuit is closed through the reverse diode of the u2 transitor (thanks to @Alex_AW)
it was revealed that the intercom circuit is closed through the reverse diode of the u2 transistor (thanks to @Alex_AW)
to prevent it, you need to add a diode according to the diagram:
![](/images/fix_error_rings.png)

Expand All @@ -43,8 +47,8 @@ If you want to use the battery version without a handset, do not turn off the so


### How to join
Reset to FN by reboot device 5 times with interval less than 10 seconds.
Reset to FN by press and hold BTN for 5 seconds.
Reset to FN by reboot the device 5 times with intervals of less than 10 seconds.
Reset to FN by pressing and holding BTN for 5 seconds.

LED will flash during reset.

Expand Down Expand Up @@ -91,7 +95,7 @@ Install `E18-MS1-PCB` only!
Do not turn off `sound` because it turns U2 forever, which will drain the battery much faster.

Since the device is in sleep mode, it cannot receive commands.
But you have the ability to set the button mode or at the time of the call.
But you can set the button mode or at the time of the call.

If any commands are in the coordinator's queue, they will be executed after a button is pressed or a call is received.

Expand All @@ -100,7 +104,7 @@ If any commands are in the coordinator's queue, they will be executed after a bu
##### The mode set by the Zigbee command `overwrites` the mode set by the button.

### Binding
The device supports direct binding of an incoming call to the onOff cluster.
The device supports the direct binding of an incoming call to the onOff cluster.

For example, you can turn on the light while a call comes to the intercom, for notification in mute mode.

Expand Down

0 comments on commit db6995d

Please sign in to comment.