forked from EnterpriseDB/repmgr
-
Notifications
You must be signed in to change notification settings - Fork 0
/
repmgr--4.2.sql
195 lines (163 loc) · 5.98 KB
/
repmgr--4.2.sql
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
-- complain if script is sourced in psql, rather than via CREATE EXTENSION
\echo Use "CREATE EXTENSION repmgr" to load this file. \quit
CREATE TABLE repmgr.nodes (
node_id INTEGER PRIMARY KEY,
upstream_node_id INTEGER NULL REFERENCES nodes (node_id) DEFERRABLE,
active BOOLEAN NOT NULL DEFAULT TRUE,
node_name TEXT NOT NULL,
type TEXT NOT NULL CHECK (type IN('primary','standby','witness','bdr')),
location TEXT NOT NULL DEFAULT 'default',
priority INT NOT NULL DEFAULT 100,
conninfo TEXT NOT NULL,
repluser VARCHAR(63) NOT NULL,
slot_name TEXT NULL,
config_file TEXT NOT NULL
);
CREATE TABLE repmgr.events (
node_id INTEGER NOT NULL,
event TEXT NOT NULL,
successful BOOLEAN NOT NULL DEFAULT TRUE,
event_timestamp TIMESTAMP WITH TIME ZONE NOT NULL DEFAULT CURRENT_TIMESTAMP,
details TEXT NULL
);
DO $repmgr$
DECLARE
DECLARE server_version_num INT;
BEGIN
SELECT setting
FROM pg_catalog.pg_settings
WHERE name = 'server_version_num'
INTO server_version_num;
IF server_version_num >= 90400 THEN
EXECUTE $repmgr_func$
CREATE TABLE repmgr.monitoring_history (
primary_node_id INTEGER NOT NULL,
standby_node_id INTEGER NOT NULL,
last_monitor_time TIMESTAMP WITH TIME ZONE NOT NULL,
last_apply_time TIMESTAMP WITH TIME ZONE,
last_wal_primary_location PG_LSN NOT NULL,
last_wal_standby_location PG_LSN,
replication_lag BIGINT NOT NULL,
apply_lag BIGINT NOT NULL
)
$repmgr_func$;
ELSE
EXECUTE $repmgr_func$
CREATE TABLE repmgr.monitoring_history (
primary_node_id INTEGER NOT NULL,
standby_node_id INTEGER NOT NULL,
last_monitor_time TIMESTAMP WITH TIME ZONE NOT NULL,
last_apply_time TIMESTAMP WITH TIME ZONE,
last_wal_primary_location TEXT NOT NULL,
last_wal_standby_location TEXT,
replication_lag BIGINT NOT NULL,
apply_lag BIGINT NOT NULL
)
$repmgr_func$;
END IF;
END$repmgr$;
CREATE INDEX idx_monitoring_history_time
ON repmgr.monitoring_history (last_monitor_time, standby_node_id);
CREATE VIEW repmgr.show_nodes AS
SELECT n.node_id,
n.node_name,
n.active,
n.upstream_node_id,
un.node_name AS upstream_node_name,
n.type,
n.priority,
n.conninfo
FROM repmgr.nodes n
LEFT JOIN repmgr.nodes un
ON un.node_id = n.upstream_node_id;
CREATE TABLE repmgr.voting_term (
term INT NOT NULL
);
CREATE UNIQUE INDEX voting_term_restrict
ON repmgr.voting_term ((TRUE));
CREATE RULE voting_term_delete AS
ON DELETE TO repmgr.voting_term
DO INSTEAD NOTHING;
/* ================= */
/* repmgrd functions */
/* ================= */
/* monitoring functions */
CREATE FUNCTION set_local_node_id(INT)
RETURNS VOID
AS 'MODULE_PATHNAME', 'set_local_node_id'
LANGUAGE C STRICT;
CREATE FUNCTION get_local_node_id()
RETURNS INT
AS 'MODULE_PATHNAME', 'get_local_node_id'
LANGUAGE C STRICT;
CREATE FUNCTION standby_set_last_updated()
RETURNS TIMESTAMP WITH TIME ZONE
AS 'MODULE_PATHNAME', 'standby_set_last_updated'
LANGUAGE C STRICT;
CREATE FUNCTION standby_get_last_updated()
RETURNS TIMESTAMP WITH TIME ZONE
AS 'MODULE_PATHNAME', 'standby_get_last_updated'
LANGUAGE C STRICT;
/* failover functions */
CREATE FUNCTION notify_follow_primary(INT)
RETURNS VOID
AS 'MODULE_PATHNAME', 'notify_follow_primary'
LANGUAGE C STRICT;
CREATE FUNCTION get_new_primary()
RETURNS INT
AS 'MODULE_PATHNAME', 'get_new_primary'
LANGUAGE C STRICT;
CREATE FUNCTION reset_voting_status()
RETURNS VOID
AS 'MODULE_PATHNAME', 'reset_voting_status'
LANGUAGE C STRICT;
CREATE FUNCTION am_bdr_failover_handler(INT)
RETURNS BOOL
AS 'MODULE_PATHNAME', 'am_bdr_failover_handler'
LANGUAGE C STRICT;
CREATE FUNCTION unset_bdr_failover_handler()
RETURNS VOID
AS 'MODULE_PATHNAME', 'unset_bdr_failover_handler'
LANGUAGE C STRICT;
CREATE FUNCTION get_repmgrd_pid()
RETURNS INT
AS 'MODULE_PATHNAME', 'get_repmgrd_pid'
LANGUAGE C STRICT;
CREATE FUNCTION get_repmgrd_pidfile()
RETURNS TEXT
AS 'MODULE_PATHNAME', 'get_repmgrd_pidfile'
LANGUAGE C STRICT;
CREATE FUNCTION set_repmgrd_pid(INT, TEXT)
RETURNS VOID
AS 'MODULE_PATHNAME', 'set_repmgrd_pid'
LANGUAGE C STRICT;
CREATE FUNCTION repmgrd_is_running()
RETURNS BOOL
AS 'MODULE_PATHNAME', 'repmgrd_is_running'
LANGUAGE C STRICT;
CREATE FUNCTION repmgrd_pause(BOOL)
RETURNS VOID
AS 'MODULE_PATHNAME', 'repmgrd_pause'
LANGUAGE C STRICT;
CREATE FUNCTION repmgrd_is_paused()
RETURNS BOOL
AS 'MODULE_PATHNAME', 'repmgrd_is_paused'
LANGUAGE C STRICT;
CREATE VIEW repmgr.replication_status AS
SELECT m.primary_node_id, m.standby_node_id, n.node_name AS standby_name,
n.type AS node_type, n.active, last_monitor_time,
CASE WHEN n.type='standby' THEN m.last_wal_primary_location ELSE NULL END AS last_wal_primary_location,
m.last_wal_standby_location,
CASE WHEN n.type='standby' THEN pg_catalog.pg_size_pretty(m.replication_lag) ELSE NULL END AS replication_lag,
CASE WHEN n.type='standby' THEN
CASE WHEN replication_lag > 0 THEN age(now(), m.last_apply_time) ELSE '0'::INTERVAL END
ELSE NULL
END AS replication_time_lag,
CASE WHEN n.type='standby' THEN pg_catalog.pg_size_pretty(m.apply_lag) ELSE NULL END AS apply_lag,
AGE(NOW(), CASE WHEN pg_catalog.pg_is_in_recovery() THEN repmgr.standby_get_last_updated() ELSE m.last_monitor_time END) AS communication_time_lag
FROM repmgr.monitoring_history m
JOIN repmgr.nodes n ON m.standby_node_id = n.node_id
WHERE (m.standby_node_id, m.last_monitor_time) IN (
SELECT m1.standby_node_id, MAX(m1.last_monitor_time)
FROM repmgr.monitoring_history m1 GROUP BY 1
);