Skip to content

Receive & parse EDF teleinfo data from meter (like the Linky)

Notifications You must be signed in to change notification settings

ztec/go_edf_teleinfo

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

2 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

EDF TELEINFO

This library offer the tools to read and parse data from French EDF energy meter. This data is called "Téléinfo" and is named Teleinfo in the library.

ALPHA STATE

I use this library on my own installation. This installation does not cover the whole specification of EDF Téléinfo, and some fields are not parsed. The full specification can be found in this document

The library provide the raw packet for anyone to use, but you are welcome to contribute

Standard & Historical formats

This library only works with the historical format. This is the format of EDF meter for decades now. The linky, the green meter, arrived with a new format called "standard" (Good luck for the next format name ...). This format must be enabled. Personally it is not enabled and I did not bother to call Enedis to do it. Only them can do it. If you do, or you meter is already "standard" enabled, then maybe j-vizcaino/goteleinfo is a better choice of library for you. I did not test it, but it seems to do the job.

How-to use the library

import the package via

go get git2.riper.fr/ztec/go_edf_teleinfo

or

go get github.com/ztec/go_edf_teleinfo

in your program you can now use it with git2.riper.fr/ztec/go_edf_teleinfo or github.com/ztec/go_edf_teleinfo in your imports.

package main

import (
	"bufio"
	"fmt"
	"git2.riper.fr/ztec/go_edf_teleinfo"
)

func main() {

	fi, err := os.Open("/dev/ttyAMA0") // Open the interface. It must be already configured with correct parameters
	if err != nil {
		fmt.Printf("ERROR %s. \n", err)
		return
	}
	defer fi.Close()

	scanner := bufio.NewScanner(fi)                // Creating a scanner reading incomming data from interface
	scanner.Split(go_edf_teleinfo.ScannerSplitter) // Adding a "content splitter" to identify each teleinfo messages

	for {
		for scanner.Scan() {
			teleinfo, err := go_edf_teleinfo.PayloadToTeleinfo(scanner.Bytes()) // Reading the latest packet  
			if err != nil {
				fmt.Printf("ERROR %s. %#v\n", err, teleinfo)
				continue
			}
			fmt.Printf("EDF TELEINFO PAYLOAD %#v\n", teleinfo) // You can now use this data as you wish
		}
	}
}

Reference

The library provide the following

Data structure

Teleinfo data is conveniently stored in the main data structure from teleinfo.go

Some data you can expect:

  • HCHC Index heures creuses in KWh or KVArh
  • HCHP Index heures pleines in KWh or KVArh
  • IINST Intensitee instantanee in A rounded to the closer integer
  • PAPP Puissance apparente in VA rounded to the tenth
  • PTEC Période tarifaire en cours (Heure creuse ou pleine ou bleu ou rouge, ...)

There is also a RAW field that hold the original Bytes.

For the full list, just review teleinfo.go

Payload parsing

PayloadToTeleinfo is a function that will analyse the given []bytes to generate a teleinfo object. It will parse each lines, and check the checksums to ensure the data is valid. Any error is raised via the Error returned.

Scanner splitter

If you decide to read from the serial interface directly in go, you can use the provided ScannerSplitter function to slice data received in coherent chunks containing all data the meter sent.

Versioning

This library is in alpha state however

  • I'll tag any new version
  • I won't break compatibility without increasing the second digit (from 0.1 to 0.2 contains breaking changes)
  • I don't consider adding new fields to Teleinfo (and the code to extract it) a breaking change
  • I consider removing a field from Teleinfo as a breaking change
  • I consider changing the name or the intention of the existing PayloadToTeleinfo and ScannerSplitter function as a breaking change

Alternative

j-vizcaino/goteleinfo seems to be doing the same job, and support the new format called "standard" of the Linky. If this library does not work for you, give it a try.

About

Receive & parse EDF teleinfo data from meter (like the Linky)

Resources

Stars

Watchers

Forks

Packages

No packages published

Languages