  • QTc is graded only where it can be trusted. Above 100 bpm, or before the heart rate has settled after effort,
    heart-rate corrections aren't reliable and a chest strap's T wave is hard to time exactly. QTc is now graded only on
    steady stretches of at least a minute at 50–100 bpm, using Bazett (the correction the normal range was set with),
    and that value is the one shown next to the range, with Fridericia beside it. Otherwise it shows Not assessed
    (rate)
    , with the values but without the normal range, so a training session no longer gets a false "borderline"
    flag. The results summary says so too. Reported by a user.
  • QTc trend chart labelled QTc (Bazett); the rate-correction check explains that a flat cloud means the rate
    dependence was removed, while the level is graded separately.
  • ECG strips no longer print a heart rate over the interval that starts at an ectopic beat (it read like a 195 bpm
    spike). The report's maximum heart rate already leaves ectopic beats out.
  • Fewer false extra beats: when the strap shifts and the heartbeat spikes shrink, the app could time a beat on the
    wrong part of the spike and call it an extra beat (one training session showed 81 instead of about 13). A late beat
    followed by an early one is now recognised as a timing slip, and extra beats are not judged where the spikes are too
    small; the report says for how long. The extra-beats card now says "beats".
  • T-wave shape is now judged on averaged beats, as the "Average beat" picture shows, instead of one beat at a
    time. When the strap's signal is small, single T waves are easily flipped by ordinary wobble, which gave false
    "Outside normal range" results on readings whose averaged T wave was clearly upright.
  • Time in zones counts only normal beat-to-beat intervals, so extra beats and timing slips no longer add seconds to the
    top zones.
  • QTc on the short side: from 330 ms is within the normal range, 320–329 ms borderline and below 320 ms outside it
    (short QT is diagnosed at 320 ms or less, and a chest strap reads QT slightly short). A resting reading of 342 ms is
    no longer flagged.
  • LTHR test: if heart rate was still climbing over the last 5 minutes, the threshold is still set but marked
    "effort did not level off". The training zones page explains why a threshold effort splits its time between Z4
    and Z5a.
  • The web version points to the Android app: a quiet "Also available as an Android app →" link at the bottom of the
    start screen, and an Android app button in About (neither shows in the Android app itself). Check for
    updates
    in About now shows only in the Android app, as intended.
  • New thank-you line: "No ads, no tracking. If you find this app useful, please consider making a small donation to
    help fund development. Thank you!"
  • Release and Android hardening from a security review: signing in a separate, approval-gated step; unused file
    sharing removed; saving writes only to the place chosen in the save screen.

Download and check

  • LeadOne-ECG-1.8.3.apk (below). Install guide: https://leadone.anonacondacodelab.com/android.html
  • SHA-256 of the APK: e245e6ed09cb736a724fdd0a3d84d327bb1242f2d3dd0650b16feb9f0788709c
  • Signing certificate SHA-256: 4D:6C:EA:58:94:C0:D7:D8:E9:AB:74:BC:3A:1E:9C:A5:47:BD:40:A2:02:B6:70:99:AF:66:5B:29:7F:7A:8F:47

Built by GitHub Actions from this tag's source code (also attached below). No internet permission.

Lead One ECG 1.8.2

Choose a tag to compare

@github-actions github-actions released this 27 Oct 05:18
b67c3e8
  • Saved files are named by date, time and recording type, like 2026-10-26_ECG_0712_morning (.pdf for the report,
    .json for the recording file), so they list in date order and readings to compare are easy to spot.
  • Results summary: Avg heart rate on every summary, including training and the orthostatic test (lying and standing).
  • Links open in the same tab.
  • Readings, reports, history and strap details are marked so a browser's Translate button leaves them out
    (translation sends the page's text to an online service). The manual explains this, and that opening the web app
    is an ordinary website visit.
  • New home: the website moved to Cloudflare Pages, with stricter security headers: no other site can show
    the app inside its own page, and browsers always use HTTPS.
  • Shorter thank-you line at the bottom of the start screen.

Download and check

  • LeadOne-ECG-1.8.2.apk (below). Install guide: https://leadone.anonacondacodelab.com/android.html
  • SHA-256 of the APK: 150b19b28f6c33f19768eaef21d45f48d7187c467b158151afa97d33886da3b4
  • Signing certificate SHA-256: 4D:6C:EA:58:94:C0:D7:D8:E9:AB:74:BC:3A:1E:9C:A5:47:BD:40:A2:02:B6:70:99:AF:66:5B:29:7F:7A:8F:47

Built by GitHub Actions from this tag's source code (also attached below). No internet permission.

Android test build 1.8.2 (build 32)

Pre-release

Choose a tag to compare

@github-actions github-actions released this 27 Oct 03:54
b67c3e8

Test build of the Android app, made automatically from commit b67c3e8. Install over the previous test build; your recordings are kept.

Lead One ECG 1.8.1

Choose a tag to compare

@github-actions github-actions released this 25 Oct 05:47
55ac17f
  • Even countdowns: the recording timer and the step, orthostatic and time-trial countdowns now tick once a second
    evenly, instead of stalling and jumping as the strap's data arrives in Bluetooth bursts.
  • Summary when a recording ends: the "Recording complete" screen now analyses the recording straight away and shows
    the report's overall verdict with 4-6 key results: heart rate and HRV (with the change from your usual), rhythm, ECG
    shape and signal quality; for training, peak heart rate, recovery and any test result; for the orthostatic test, the
    rise on standing and HRV lying and standing. View full report then opens instantly. Suggested by a user.
  • Sharper audio cues on Android phones: the orthostatic "stand now" beep, the ramp and DFA step beeps and the end of the
    LTHR time trial are scheduled slightly ahead to allow for the phone's audio delay, so you hear them as the screen
    changes. Cues still waiting are cancelled when you pause, stop or start recovery, and no cues sound while paused.
    Measurements are unaffected: they come from the heartbeat data, not from when a beep is heard.

Download and check

  • LeadOne-ECG-1.8.1.apk (below). Install guide: https://leadone.anonacondacodelab.com/android.html
  • SHA-256 of the APK: 1f26d7944c75c4479d9d16f59c1665a6e4a1c58201b9135998e71ba7ea6bcec7
  • Signing certificate SHA-256: 4D:6C:EA:58:94:C0:D7:D8:E9:AB:74:BC:3A:1E:9C:A5:47:BD:40:A2:02:B6:70:99:AF:66:5B:29:7F:7A:8F:47

Built by GitHub Actions from this tag's source code (also attached below). No internet permission.

Lead One ECG 1.8.0

Choose a tag to compare

@github-actions github-actions released this 22 Oct 06:33
3cccb90

Download and check

  • LeadOne-ECG-1.8.0.apk (below). Install guide: https://leadone.anonacondacodelab.com/android.html
  • SHA-256 of the APK: 540ea4de370edfcff2f1f10ada9934d8ec8ea05332e3d0da5473190716d341c0
  • Signing certificate SHA-256: 4D:6C:EA:58:94:C0:D7:D8:E9:AB:74:BC:3A:1E:9C:A5:47:BD:40:A2:02:B6:70:99:AF:66:5B:29:7F:7A:8F:47

Built by GitHub Actions from this tag's source code (also attached below). No internet permission.