@vtnate I'd recommend using the EER for the SEER 14 AC from BEopt, as that's probably what the person who created the upgrade used. Hopefully it's reasonably consistent with what you found. (Note that BEopt directly gets its data from the REMDB, so fridge/freezer should already be consistent.) |
@shorowit Got it, thanks for the explaining that connection. Yes, fridge/freezer are already consistent. Looks like BEOpt used a rounded version of what I had for EER. I updated options_lookup to match BEOpt. |
resources/options_lookup.tsv
Outdated
Misc Freezer None ResidentialMiscLargeUncommonLoads has_freezer=false freezer_rated_annual_energy=935 freezer_mult=0.342 "freezer_weekday_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_weekend_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_monthly_sch=0.837, 0.835, 1.084, 1.084, 1.084, 1.096, 1.096, 1.096, 1.096, 0.931, 0.925, 0.837" freezer_location=auto | ||
Misc Freezer "EF 12, National Average" ResidentialMiscLargeUncommonLoads has_freezer=true freezer_rated_annual_energy=935 freezer_mult=0.342 "freezer_weekday_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_weekend_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_monthly_sch=0.837, 0.835, 1.084, 1.084, 1.084, 1.096, 1.096, 1.096, 1.096, 0.931, 0.925, 0.837" freezer_location=auto | ||
Misc Freezer "EF 16, 2001 Fed Standard (reference freezer)" ResidentialMiscLargeUncommonLoads has_freezer=true freezer_rated_annual_energy=712 freezer_mult=0.342 "freezer_weekday_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_weekend_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_monthly_sch=0.837, 0.835, 1.084, 1.084, 1.084, 1.096, 1.096, 1.096, 1.096, 0.931, 0.925, 0.837" freezer_location=auto | ||
Misc Freezer "EF 18, 2008 Energy Star" ResidentialMiscLargeUncommonLoads has_freezer=true freezer_rated_annual_energy=641 freezer_mult=0.342 "freezer_weekday_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_weekend_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_monthly_sch=0.837, 0.835, 1.084, 1.084, 1.084, 1.096, 1.096, 1.096, 1.096, 0.931, 0.925, 0.837" freezer_location=auto | ||
Misc Freezer "EF 20, 2008 Energy Star Most Efficient" ResidentialMiscLargeUncommonLoads has_freezer=true freezer_rated_annual_energy=568 freezer_mult=0.342 "freezer_weekday_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_weekend_sch=0.040, 0.039, 0.038, 0.037, 0.036, 0.036, 0.038, 0.040, 0.041, 0.041, 0.040, 0.040, 0.042, 0.042, 0.042, 0.041, 0.044, 0.048, 0.050, 0.048, 0.047, 0.046, 0.044, 0.041" "freezer_monthly_sch=0.837, 0.835, 1.084, 1.084, 1.084, 1.096, 1.096, 1.096, 1.096, 0.931, 0.925, 0.837" freezer_location=auto |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
freezer_mult=0.342
should be freezer_mult=
1.0` for these three, assuming you want them to have a "whole freezer" as opposed to a "national average fraction of a freezer".
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
🤦♂ Yuuuup thanks.
Add items to options_lookup available in master branch
Energy usage for fridge/freezers came from https://remdb.nrel.gov/
EER was calculated from SEER (for SEER 14 AC) using this calculator: https://power-calculation.com/EER_SEER_COP_conversion_air_conditioning.phpEER was copied from BEOpt, which gets its data from https://remdb.nrel.gov/