Log the issue-23 fix in the changelog and in Known Limitations
Record WT-84 (issue 23: the listener's ceiling is a concurrency cap) and WT-85
C99: fix the status count, record WT-83 and the gate mistake
C99: record the thirty-third part (the peer's connection IDs)
C99: record the thirty-second part (issuing connection IDs)
C99: record the thirty-first part (Retry tag) and add WT-82 for the missing A.4 vector
C99: record the thirtieth part (STOP_SENDING)
C99: record the twenty-ninth part (a lost stream packet names what to resend)
C99: record the twenty-eighth part (a sender can cancel a stream)
C99: record the twenty-seventh part and sync the status count (75,880)
C99: close WT-81 in the tracker addendum and sync the status count (75,847) Parts 25 and 26 of the stream layer are recorded in an addendum rather than in the phase row, because two anchor-based edits to that row failed and appending is the pattern that works in this file. The diagnosis stays: the stream module reports a per-stream overrun and a final-size contradiction with the same status, which is why the caller must ask each limit in turn.
C99: WT-81 records the flow-control-on-receive diagnosis and the two outstanding rows wt_quic_stream_on_data returns WT_ERR_PROTOCOL for both a per-stream limit overrun and a final-size contradiction, so the caller cannot map the status to an error code by itself; the connection must compare the frame's end against the stream's limit. The round-53 attempt failed on exactly that, with a test seed that never applied. Recorded with the exit criterion, and with the phase-4 row note that still needs the twenty-fifth part.
C99: Phase 4 twenty-fifth part (reset and stop reach the state machines)
C99: WT-80 closed and the status count measured (75,820) The twenty-fourth part landed at 0d927c7 after the sender bug it exposed was fixed. The two rows the previous round left in the tracker are replaced by one closed row that keeps the findings: the sender rule for a peer's unidirectional stream, the handshake test's stream-3 send, and the fact that stream-count grants have to come before the STREAM frame that needs them. The status count is the measured one.
C99: WT-80 records the sender bug the stream-creation rule exposed
C99: Phase 4 twenty-fourth part (streams created by their first frame), tracker and status
C99: Phase 4 twenty-third part (opening a stream), tracker and status
C99: Phase 4 twenty-second part (the stream table), tracker and status
C99: measured test count after the stream-number helpers
C99: correct the test count
C99: Phase 4 twenty-first part (stream number fields), tracker and status
C99: WT-79 parked after a fourth attempt, with the cause and the decision The fourth attempt fixed the cause the third exposed: the padding was aimed at the floor by arithmetic, so the rebuilt packet was two bytes above the path's maximum and every Initial packet a client sent was refused -- which is also what made the earlier attempts look like hangs, since nothing arrived and every wait expired its full timeout. With the padding measured rather than computed, the handshake test still passes 240 checks and the connection test still does not finish, so a fifth unknown remains there. Parked deliberately: this is anti-amplification hardening, not a prerequisite -- the handshake completes and interoperates without it and nothing depends on it -- and four sessions' budgets have gone into it. WT-78 (the stream layer) is what the phase and everything after it needs.
C99: WT-79 records that the client padding alone breaks 76 connection checks The two halves were measured separately. With the client padding alone -- no server discard, so no packet can be refused for its size -- test_quic_connection still fails 76 of 401 checks while test_quic_handshake passes unchanged. So the entanglement is not only the server-side rule: the existing tests' expectations depend on the sizes the client sends, and where has to be measured rather than reasoned about. Recorded so the next attempt starts by instrumenting.
C99: WT-79 carries the finding from the first attempt Both halves of the 1200-byte Initial rule were written and compiled, but the test binary went from under a second to over a minute. The floor applies to the hand-built Initial packets the existing tests send TO a server on purpose -- to have them refused for the address or the connection ID -- so the floor refuses them first and every following wait expires its full timeout. Recorded with the two places the next attempt has to touch, rather than left as a mystery.
C99: WT-79 records the missing 1200-byte Initial datagram rule RFC 9000 section 14.1 asks a client to pad Initial datagrams to at least 1200 bytes and a server to discard an Initial packet in a smaller datagram. The runtime does neither, and the two halves have to land together: enforcing the server's discard alone would refuse the runtime's own handshake. Recorded with an exit criterion rather than left implicit, since the floor is what makes the handshake's anti-amplification budget meaningful.
C99: WT-78 records the stream layer as the largest remaining Phase 4 item The runtime has the wire half of streams (a STREAM frame encoder, the peer's granted limits checked, the limits this endpoint grants advertised) and none of the state: no stream table, no flow control accounting, no retransmission of stream data, no RESET_STREAM or STOP_SENDING handling and no receive reassembly. Recorded as its own task with an exit criterion, because the phase row alone hides how much is there.
C99: Phase 4 twentieth part (the frame-permission rule), tracker and status
C99: Phase 4 nineteenth part (HANDSHAKE_DONE only reaches a client), tracker and status
C99: Phase 4 eighteenth part (a closed connection ignores frames), tracker and status