@@ -0,0 +1,230 @@
/**
* Copyright 2020 SmartThings
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
* Generic Z-Wave Water/Temp/Humidity Sensor
*
* Author: SmartThings
* Date: 2020-07-06
*/

metadata {
definition(name: "Z-Wave Water/Temp/Humidity Sensor", namespace: "smartthings", author: "SmartThings", mnmn: "SmartThings", vid: "generic-leak-5", ocfDeviceType: "x.com.st.d.sensor.moisture") {
capability "Water Sensor"
capability "Temperature Measurement"
capability "Relative Humidity Measurement"
capability "Tamper Alert"
capability "Battery"
capability "Sensor"
capability "Health Check"
capability "Configuration"

fingerprint mfr:"0371", prod:"0002", model:"0013", deviceJoinName: "Aeotec Water Leak Sensor", mnmn: "SmartThings", vid: "aeotec-water-sensor-7-pro" //EU //Aeotec Water Sensor 7 Pro
fingerprint mfr:"0371", prod:"0102", model:"0013", deviceJoinName: "Aeotec Water Leak Sensor", mnmn: "SmartThings", vid: "aeotec-water-sensor-7-pro" //US //Aeotec Water Sensor 7 Pro
fingerprint mfr:"0371", prod:"0202", model:"0013", deviceJoinName: "Aeotec Water Leak Sensor", mnmn: "SmartThings", vid: "aeotec-water-sensor-7-pro" //AU //Aeotec Water Sensor 7 Pro
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I assume that the need for a device-specific vid is because of custom ranges? Let's also create a generic-leak-5 which takes generic-leak-3 and adds humidity.

Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

also this vid should be at the DTH level, right? and doesn't need to be per-device?

}

tiles(scale: 2) {
multiAttributeTile(name: "water", type: "generic", width: 6, height: 4) {
tileAttribute("device.water", key: "PRIMARY_CONTROL") {
attributeState("dry", label:'${name}', icon: "st.alarm.water.dry", backgroundColor: "#ffffff")
attributeState("wet", label:'${name}', icon: "st.alarm.water.wet", backgroundColor: "#00A0DC")
}
}
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "battery", label: '${currentValue}% battery'
}
valueTile("humidity", "device.humidity", inactiveLabel: false, width: 2, height: 2) {
state "humidity", label: '${currentValue}% humidity', unit: ""
}
valueTile("temperature", "device.temperature", width: 2, height: 2) {
state("temperature", label: '${currentValue}°',
backgroundColors: [
// Celsius
[value: 0, color: "#153591"],
[value: 7, color: "#1e9cbb"],
[value: 15, color: "#90d2a7"],
[value: 23, color: "#44b621"],
[value: 28, color: "#f1d801"],
[value: 35, color: "#d04e00"],
[value: 37, color: "#bc2323"],
// Fahrenheit
[value: 40, color: "#153591"],
[value: 44, color: "#1e9cbb"],
[value: 59, color: "#90d2a7"],
[value: 74, color: "#44b621"],
[value: 84, color: "#f1d801"],
[value: 95, color: "#d04e00"],
[value: 96, color: "#bc2323"]
])
}
valueTile("tamper", "device.tamper", height: 2, width: 2, decoration: "flat") {
state "clear", label: 'tamper clear', backgroundColor: "#ffffff"
state "detected", label: 'tampered', backgroundColor: "#ff0000"
}

main "water"
details(["water", "humidity", "temperature", "battery", "tamper"])
}
}

def installed() {
clearTamper()
response([
secure(zwave.batteryV1.batteryGet()),
"delay 500",
secure(zwave.notificationV3.notificationGet(notificationType: 0x05)), // water
"delay 500",
secure(zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x01)), // temperature
"delay 500",
secure(zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x05)), // humidity
"delay 10000",
secure(zwave.wakeUpV2.wakeUpNoMoreInformation())
])
}

def updated() {
configure()
}

def configure() {
sendEvent(name: "checkInterval", value: 8 * 60 * 60 + 10 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}

def parse(String description) {
def results = []

if (description.startsWith("Err")) {
results += createEvent(descriptionText: description, displayed: true)
} else {
def cmd = zwave.parse(description)
if (cmd) {
results += zwaveEvent(cmd)
}
}

log.debug "parse() result ${results.inspect()}"

return results
}

def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand()

if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
} else {
log.warn "Unable to extract encapsulated cmd from $cmd"
createEvent(descriptionText: cmd.toString())
}
}

def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cmd) {
if (cmd.notificationType == 0x05) {
if (cmd.event == 0x01 || cmd.event == 0x02) {
sensorWaterEvent(1)
} else if (cmd.event == 0x00) {
sensorWaterEvent(0)
}
} else if (cmd.notificationType == 0x07) {
if (cmd.event == 0x03) {
runIn(10, clearTamper, [overwrite: true, forceForLocallyExecuting: true])
createEvent(name: "tamper", value: "detected", descriptionText: "$device.displayName was tampered")
} else if (cmd.event == 0x00) {
createEvent(name: "tamper", value: "clear")
}
}
}

def zwaveEvent(physicalgraph.zwave.commands.sensorbinaryv2.SensorBinaryReport cmd) {
return sensorWaterEvent(cmd.sensorValue)
}

def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
return sensorWaterEvent(cmd.value)
}

def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [name: "battery", unit: "%", isStateChange: true]
state.lastbatt = now()

if (cmd.batteryLevel == 0xFF) {
map.value = 1
map.descriptionText = "$device.displayName battery is low!"
} else {
map.value = cmd.batteryLevel
}

createEvent(map)
}

def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) {
def map = [:]

switch (cmd.sensorType) {
case 0x01:
map.name = "temperature"
map.unit = temperatureScale
map.value = convertTemperatureIfNeeded(cmd.scaledSensorValue, cmd.scale == 1 ? "F" : "C", cmd.precision)
break
case 0x05:
map.name = "humidity"
map.value = cmd.scaledSensorValue.toInteger()
map.unit = "%"
break
default:
map.descriptionText = cmd.toString()
}

createEvent(map)
}

def zwaveEvent(physicalgraph.zwave.commands.wakeupv2.WakeUpNotification cmd) {
def cmds = []
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Please break code blocks up (not just in this function) with empty lines so that the code is easier to read. For example, an empty line after variable declarations, and empty line before and after if statements, and an empty line before return statements.

def result = createEvent(descriptionText: "$device.displayName woke up", isStateChange: false)
cmds += secure(zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x05))
cmds += secure(zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x01))

if (!state.lastbatt || (now() - state.lastbatt) >= 10 * 60 * 60 * 1000) {
cmds += ["delay 1000",
secure(zwave.batteryV1.batteryGet()),
"delay 2000"
]
}

cmds += secure(zwave.wakeUpV2.wakeUpNoMoreInformation())

[result, response(cmds)]
}

def zwaveEvent(physicalgraph.zwave.Command cmd) {
log.warn "Unhandled command: ${cmd}"
}

def sensorWaterEvent(value) {
if (value) {
createEvent(name: "water", value: "wet", descriptionText: "$device.displayName detected water leakage")
} else {
createEvent(name: "water", value: "dry", descriptionText: "$device.displayName detected that leakage is no longer present")
}
}

def clearTamper() {
sendEvent(name: "tamper", value: "clear")
}

private secure(cmd) {
if (zwaveInfo.zw.contains("s")) {
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
} else {
cmd.format()
}
}