In Development. Telemetry, diagnostics, and settings reads work reliably over both supported families.

As an alternative to the HYXI Cloud API, the integration can talk directly to one inverter over RS485 Modbus:

  • No developer account, no Access/Secret Key, no internet dependency.
  • Polls far faster than the cloud allows.
  • Gives access to some settings the cloud API doesn't expose control for.
  • Trade-off: only one device (no multi-device discovery, no real-time push, no remote access away from your LAN).

Supported models

Family Models Register map source
Hybrid Inverter HYX-H(5~12)K-HT (incl. H10K-HT), HYX-H(15~25)K-HT, HYX-H(6~15)K-HTA, HYX-H(6~15)K-HTAC HYXIPower RS485_MODBUS RTU Hybrid Inverter Protocol, V4.1
Micro ESS (HALO) HYX-MS3000AC HYXIPower Micro Storage RS485 MODBUS protocol, V1.0

Both maps cover live telemetry (grid/off-grid power, PV strings, battery/BMS detail, energy counters) and β€” once you enable Device Control & Protection β€” the mode buttons (Idle / Charge / Discharge / Self-Consume), Charge/Discharge Power numbers, the Battery Dispatch Control switch, and a slice of hardware settings (feed-in power limit, SOC setpoints, anti-starvation, plus power on/off/restart buttons on Hybrid) as number and switch entities. The settings block is re-read hourly, and a Refresh Settings button forces an immediate re-read after you change something from the HYXI app or another Modbus master. See Device Control for the full per-family control list, and Local Energy Manager β€” which runs over Modbus too, including on a HALO.

Every register's provenance β€” which vendor document it came from, what's confirmed against real hardware vs. inferred, and known caveats β€” is tracked in docs/modbus-provenance.md in the repo. That file is the source of truth if a value looks wrong; this page is just the setup guide.

Wiring

Family Connector Pins Serial settings
Hybrid Inverter Inverter's COM port (RJ45) PIN5 = RS485 A (white/blue), PIN6 = RS485 B (green); other pins unused 115200bps, no parity, 8 data bits, 1 stop bit
Micro ESS (HALO) RJ45 in a circular weatherproof housing (not in HYXI's protocol document) PIN7 = RS485 A (white/brown), PIN8 = RS485 B (brown); other pins unused (from HYXI, not in the protocol document β€” see below) 115200bps, no parity, 8 data bits, 1 stop bit

Both families also require a minimum gap between messages before the next one β€” Hybrid: >500ms, HALO: >200ms β€” which the integration applies automatically once it detects your family, so it's nothing you need to configure, but it's worth knowing if you're troubleshooting timeouts on a slower adapter.

Hybrid Inverter

Hybrid inverter RS485 pinout: RJ45 COM port in T568B order, pin 5 (white/blue) = RS485 A, pin 6 (green) = RS485 B

From HYXI's RS485_MODBUS RTU Hybrid Inverter Protocol V4.1. Note that pins 5 and 6 are not a single twisted pair in a T568B cable (the blue pair is 4/5, the green pair is 3/6), so for anything beyond a short run, land one dedicated twisted pair on pins 5 and 6 rather than using a straight patch cable as-is.

Micro ESS (HALO)

HALO RS485 pinout: RJ45 in T568B order, pin 7 (white/brown) = RS485 A, pin 8 (brown) = RS485 B, pins 1–6 unused

HALO's pinout isn't in HYXI's own protocol document β€” that gives only the serial parameters above, no pin numbers, no connector type. The PIN7/8 assignment comes from issue #662 and a matching Home Assistant community post, from the contributor who supplied the HALO protocol document itself, relaying HYXI's answers. HYXI has given it twice: first as "PIN7 = A, PIN8 = B … white-brown and brown", then β€” on a re-confirmation request β€” as "from right to left, first pin 485B then 485A, other pins idle", which is the same pair counted from the other end. So A on the white-brown wire, B on the brown wire, nothing else connected; the port is a normal RJ45 inside a circular weatherproof shell, so the T568B colours apply. Many HALO owners now run the integration over Modbus day to day. Don't assume the HALO matches the Hybrid's PIN5/6 layout. Getting A/B backwards won't damage anything β€” if the bus doesn't enumerate, swap them.

Setup

You don't need to know your exact inverter family or wire framing ahead of time β€” the integration probes the bus during setup and detects both automatically.

  1. Wire your RS485 adapter to the inverter per the table above.
  2. Go to Settings > Devices & Services > Add Integration > HYXI.
  3. Choose Local Modbus (RS485, no account) as the transport.
  4. Choose your connection type:
    • Serial port β€” a USB RS485 adapter plugged directly into the Home Assistant host. Enter the device path and baud rate.
    • Modbus TCP gateway β€” an RS485-to-Ethernet adapter. See Configuring a TCP gateway below.
  5. Enter the slave address (unit ID) β€” 1 is the usual default.
  6. Submit. The integration probes the bus, identifies the family, and creates the matching entities.

Configuring a TCP gateway

If you're using an RS485-to-Ethernet gateway rather than a USB adapter, its serial side needs to match the table above β€” 115200bps, no parity, 8 data bits, 1 stop bit for either family. Beyond that:

  • Protocol/mode β€” either works, and both are detected automatically: a gateway that speaks native Modbus-TCP/MBAP framing and translates to RTU on the wire (e.g. Waveshare's "Modbus TCP to RTU") is tried first, then a transparent/passthrough gateway that just tunnels raw RTU frames over TCP (e.g. Waveshare's "Protocol: None"). You don't need to know which yours is, but if your gateway lets you pick, the MBAP-translating mode gets identified fastest.
  • Port β€” 502 is the Modbus-TCP default; use whatever the gateway is actually configured to.
  • Slave/unit ID β€” must match the inverter's own Modbus address, not an address you invent for the gateway. Both families default to 1: Hybrid's address lives in register 3121, HALO's in register 4004 β€” change it on the inverter/HALO itself first if you need something else.

Known caveats

  • Battery control is local-only. HYXI's cloud doesn't forward battery commands sent with owners' API keys (see Device Control). Over local Modbus that restriction doesn't apply: both the HALO and the Hybrid get the mode buttons (Idle/Charge/Discharge/Self-Consume) and charge/discharge power numbers β€” on the HALO driven by the register map's VPP dispatch block β€” plus the Local Energy Manager.
  • Battery Dispatch Control releases the battery β€” except on a restart. Turning the switch off, disabling Device Control, or deleting the entry hands the battery back to the inverter's own work mode. A Home Assistant shutdown or restart does not β€” whatever mode was last set stays active until HA comes back and takes over again.
  • Some writes are still being validated against hardware. Reads are reliable on both families; the control writes are documented but not all confirmed on a live unit. docs/modbus-provenance.md tracks what's confirmed vs. inferred, including whether clearing dispatch cleanly resumes the configured work mode on a real HALO.

Something's wrong

  • Wrong device type, sensors stuck at zero, or the bus won't come up β€” Local Modbus Troubleshooting has a read-only diagnostic script and a checklist.