Modbus Simulator

This repository provides a lightweight Modbus TCP server simulator written in Go. Register addresses and CSV data bindings are configured using a TOML file. The simulator reads data from a CSV file and periodically updates the Modbus registers with the configured values.

Features

  • Minimal Modbus TCP server that supports reading coils, discrete inputs, holding registers, and input registers.
  • TOML configuration to define server settings, update interval, and register bindings.
  • CSV-driven data updates that cycle through rows on a fixed interval.
  • Optional scaling, offset, and data type conversion for numeric registers.

Getting Started

  1. Install Go – version 1.20 or later is recommended.
  2. Clone this repository and change into the project directory.
  3. Create a configuration file based on config.example.toml.
  4. Prepare a CSV file containing the columns referenced in the configuration.
# Example
cp config.example.toml config.toml

The example configuration references data/example_data.csv, which contains sample telemetry rows.

Running the simulator

go run ./cmd/server --config config.toml

The server listens on the address configured in the TOML file (default :1502) and will rotate through the CSV rows on the configured interval, updating the Modbus register values accordingly.

Use any Modbus TCP client to read from the configured registers. The simulator supports the following Modbus function codes:

  • 0x01 – Read Coils
  • 0x02 – Read Discrete Inputs
  • 0x03 – Read Holding Registers
  • 0x04 – Read Input Registers

Configuration Reference

  • csv_file: Path to the CSV file containing data rows.
  • update_interval: Go duration string that controls how often registers are updated (e.g., "5s").
  • [server] section:
    • listen_address: TCP address for the Modbus server (default :1502).
  • [[registers]] array:
    • type: Register type (holding, input, coil, or discrete).
    • address: Register address to update.
    • csv_column: Column name in the CSV file to use for the register value.
    • scale: Optional multiplier applied to the CSV value before it is written to the register (defaults to 1).
    • offset: Optional value added after scaling (defaults to 0).
    • data_type: Optional numeric representation for holding and input registers. Supported values are uint16, int16, and float32. Float32 values consume two consecutive registers starting at address.

The simulator loops through the CSV rows continuously. Coil and discrete input values treat any non-zero (after applying scale and offset) CSV value as true.

About

A simulator of modbus server, read data from csv file, update data periodly.