Skip to content

Commit 92ba865

Browse files
committed
Updated OZW configuration files
1 parent e13d8e4 commit 92ba865

File tree

4 files changed

+78
-14
lines changed

4 files changed

+78
-14
lines changed

Config/SensorMultiLevelCCTypes.xml

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -1,5 +1,5 @@
11
<?xml version="1.0" encoding="utf-8"?>
2-
<SensorTypes xmlns='https://github.com/OpenZWave/open-zwave' Revision="3">
2+
<SensorTypes xmlns='https://github.com/OpenZWave/open-zwave' Revision="4">
33
<SensorType id="1" name="Air Temperature">
44
<SensorScale id="0" name="Celsius">C</SensorScale>
55
<SensorScale id="1" name="Fahrenheit">F</SensorScale>
@@ -14,7 +14,7 @@
1414
<SensorScale id="1" name="Lux">Lux</SensorScale>
1515
</SensorType>
1616
<SensorType id="4" name="Power">
17-
<SensorScale id="0" name="Watt">Watt</SensorScale>
17+
<SensorScale id="0" name="Watt">W</SensorScale>
1818
<SensorScale id="1" name="Btu/h">Btu/h</SensorScale>
1919
</SensorType>
2020
<SensorType id="5" name="Humidity">

Config/manufacturer_specific.xml

Lines changed: 11 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -1,6 +1,6 @@
11
<?xml version="1.0" encoding="utf-8"?>
22

3-
<ManufacturerSpecificData Revision="88" xmlns="https://github.com/OpenZWave/open-zwave">
3+
<ManufacturerSpecificData Revision="93" xmlns="https://github.com/OpenZWave/open-zwave">
44
<Manufacturer id="0028" name="2B Electronics"></Manufacturer>
55
<Manufacturer id="0098" name="2GIG Technologies">
66
<Product config="2gig/ct50e.xml" id="015e" name="CT50e Thermostat" type="3200"/>
@@ -422,7 +422,7 @@
422422
<Manufacturer id="032E" name="DEFARO"></Manufacturer>
423423
<Manufacturer id="040D" name="Delaney Hardware"></Manufacturer>
424424
<Manufacturer id="0031" name="Destiny Networks"></Manufacturer>
425-
<Manufacturer id="0175" name="Devolo home Control">
425+
<Manufacturer id="0175" name="devolo Home Control">
426426
<Product config="devolo/mt2646.xml" id="0011" name="Metering Plug MT02646" type="0001"/>
427427
<Product config="devolo/mt02792.xml" id="0012" name="Smart Metering Plug MT02792" type="0001"/>
428428
<Product config="devolo/mt02648.xml" id="000e" name="Door/Window Contact MT02648" type="0002"/>
@@ -436,6 +436,8 @@
436436
<Product config="devolo/mt2653.xml" id="0102" name="Key MT2653" type="0100"/>
437437
<Product config="devolo/mt2651.xml" id="04a4" name="Smoke Detector MT2651" type="2004"/>
438438
<Product config="devolo/mt2651.xml" id="2004" name="Smoke Detector MT2651" type="2004"/>
439+
<Product config="devolo/mt2761.xml" id="0052" name="Home Control Shutter FM MT2761" type="0003"/>
440+
<Product config="devolo/mt2759.xml" id="0052" name="Home Control Switch FM MT2759" type="0002"/>
439441
</Manufacturer>
440442
<Manufacturer id="0103" name="Diehl AKO">
441443
<Product config="diehlcontrols/766366.xml" id="0002" name="Dimmer Actuator" type="0002"/>
@@ -643,6 +645,7 @@
643645
<Product config="fibaro/fgr221.xml" id="0109" name="FGR221 Roller Shutter Controller" type="0300"/>
644646
<Product config="fibaro/fgrm222.xml" id="1001" name="FGRM222 Roller Shutter Controller 2" type="0301"/>
645647
<Product config="fibaro/fgrm222.xml" id="1000" name="FGRM222 Roller Shutter Controller 2" type="0302"/>
648+
<Product config="fibaro/fgrm222.xml" id="3000" name="FGRM222 Roller Shutter Controller 2" type="0302"/>
646649
<Product config="fibaro/fgrm222.xml" id="4000" name="FGRM222 Roller Shutter Controller 2" type="0302"/>
647650
<Product config="fibaro/fgr223.xml" id="1000" name="FGRM223 Roller Shutter Controller 3" type="0303"/>
648651
<Product config="fibaro/fgs211.xml" id="0104" name="FGS211 Switch 3kW" type="0400"/>
@@ -658,6 +661,7 @@
658661
<Product config="fibaro/fgs212.xml" id="4002" name="FGS212 Switch 3kW" type="0402"/>
659662
<Product config="fibaro/fgs213.xml" id="1000" name="FGS213 Switch" type="0403"/>
660663
<Product config="fibaro/fgs213.xml" id="2000" name="FGS213 Switch" type="0403"/>
664+
<Product config="fibaro/fgs213.xml" id="3000" name="FGS213 Switch" type="0403"/>
661665
<Product config="fibaro/fgs213.xml" id="4000" name="FGS213 Switch" type="0403"/>
662666
<Product config="fibaro/fgs221.xml" id="0104" name="FGS221 Double Relay Switch 2x1.5kW" type="0200"/>
663667
<Product config="fibaro/fgs221.xml" id="0105" name="FGS221 Double Relay Switch 2x1.5kW" type="0200"/>
@@ -928,6 +932,7 @@
928932
<Product config="honeywell/39348-zw4008.xml" id="3135" name="39348 / ZW4008 In-Wall Smart Switch" type="4952"/>
929933
<Product config="honeywell/39357-ZW3004.xml" id="3130" name="39357 / ZW3004 In-Wall Smart Toggle Dimmer" type="4944"/>
930934
<Product config="honeywell/39351-ZW3010.xml" id="3235" name="39351 / ZW3010 In-Wall Smart Dimmer" type="4944"/>
935+
<Product config="honeywell/39358-ZW4002.xml" id="3131" name="39358 / ZW4002 In-Wall Fan Control" type="4944"/>
931936
</Manufacturer>
932937
<Manufacturer id="0313" name="Hoppe"></Manufacturer>
933938
<Manufacturer id="0377" name="HORNBACH Baumarkt AG"></Manufacturer>
@@ -1174,6 +1179,7 @@
11741179
<Product config="mcohome/mh8fceu.xml" id="3102" name="MH8-FC4-EU Thermostat" type="0802"/>
11751180
<Product config="mcohome/mh9co2.xml" id="0201" name="MH9-CO2-WD CO2 Monitor" type="0905"/>
11761181
<Product config="mcohome/mh9co2.xml" id="3102" name="MH9-CO2-WD CO2 Monitor" type="0901"/>
1182+
<Product config="mcohome/mh9co2.xml" id="5102" name="MH9-CO2-WD CO2 Monitor" type="0902"/>
11771183
<Product config="mcohome/a8-9.xml" id="1352" name="A8-9 Multi-sensor" type="a800"/>
11781184
<Product config="mcohome/a8-9.xml" id="1352" name="A8-9 Multi-sensor" type="a803"/>
11791185
<Product config="mcohome/mh7h.xml" id="5102" name="MH7H Water/Electrical Heating Thermostat" type="0701"/>
@@ -1218,6 +1224,9 @@
12181224
</Manufacturer>
12191225
<Manufacturer id="0083" name="MTC Maintronic"></Manufacturer>
12201226
<Manufacturer id="0143" name="myStrom"></Manufacturer>
1227+
<Manufacturer id="0438" name="Namron">
1228+
<Product config="namron/1402756.xml" id="0202" type="0002" name="LED Dimmer Z-Wave 200W"/>
1229+
</Manufacturer>
12211230
<Manufacturer id="016E" name="Nanjing Easthouse Electrical Co"></Manufacturer>
12221231
<Manufacturer id="0121" name="Napco Security Technologies, Inc.">
12231232
<Product id="0001" name="I-Bridge Z-Wave Controller" type="0001"/>

Config/mcohome/mh9co2.xml

Lines changed: 13 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -1,11 +1,23 @@
11
<?xml version="1.0" encoding="utf-8"?>
2-
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="1">
2+
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="2">
33
<!--MCOHome CO2 Monitor MH9-CO2-WD -->
44
<!-- Configuration -->
55
<CommandClass id="112">
66
<Value type="short" genre="config" instance="1" index="1" label="CO2 Notification threshold" size="2" min="1" max="1200" units="ppm" value="1000">
77
<Help>CO2 Notification threshold 1 to 2000ppm</Help>
88
</Value>
9+
<Value genre="config" index="2" instance="1" label="CO2 reporting threshold" max="100" min="0" size="1" type="byte" units="" value="10">
10+
<Help>0 report disabled, base on 5ppm unit, 10 by default, 10*5ppm=50ppm</Help>
11+
</Value>
12+
<Value genre="config" index="3" instance="1" label="Temperature reporting threshold" max="100" min="0" size="1" type="byte" units="" value="1">
13+
<Help>0 report disabled, base on 0.5C unit, 1 by default, 1*0.5C=0.5C</Help>
14+
</Value>
15+
<Value genre="config" index="4" instance="1" label="Humidity reporting threshold" max="50" min="0" size="1" type="byte" units="" value="2">
16+
<Help>0 report disabled, base on 1% unit, 2 by default, 2*1C=2C</Help>
17+
</Value>
18+
<Value genre="config" index="255" instance="1" label="Factory setting" max="255" min="0" size="1" type="byte" units="" value="0">
19+
<Help>Restore the factory setting - write only, set to 85 to reset</Help>
20+
</Value>
921
</CommandClass>
1022
<!-- Association Groups -->
1123
<CommandClass id="133">

Config/zooz/zen16.xml

Lines changed: 52 additions & 9 deletions
Original file line numberDiff line numberDiff line change
@@ -1,5 +1,5 @@
11
<?xml version="1.0" encoding="utf-8"?>
2-
<Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
2+
<Product Revision="3" xmlns="https://github.com/OpenZWave/open-zwave">
33
<MetaData>
44
<MetaDataItem name="Name">Multirelay</MetaDataItem>
55
<MetaDataItem name="Description">PRODUCT FEATURES:
@@ -37,6 +37,7 @@ SPECIFICATIONS:
3737
<MetaDataItem id="A00A" name="Identifier" type="A000">ZEN16</MetaDataItem>
3838
<ChangeLog>
3939
<Entry author="David Alden - dave@alden.name" date="16 Feb 2020" revision="2">Initial Metadata Import</Entry>
40+
<Entry author="Brad Parker - https://github.com/bepsoccer" date="6 May 2020" revision="3">Updated for firmware version 1.02</Entry>
4041
</ChangeLog>
4142
</MetaData>
4243

@@ -52,30 +53,33 @@ SPECIFICATIONS:
5253
<Item label="relays 1/2 restore, 3/4 forced off" value="3"/>
5354
<Item label="relays 1/2 restore, 3/4 forced on" value="4"/>
5455
</Value>
55-
<Value type="list" genre="config" index="2" label="Switch Type for Relay 1 (Sw1)" size="1" min="0" max="2" value="2">
56+
<Value type="list" genre="config" index="2" label="Switch Type for Relay 1 (Sw1)" size="1" min="0" max="3" value="2">
5657
<Help>Switch Type for Relay 1 (Sw1). Choose the wall switch type you want to connect to the Sw1 terminal. Default: toggle switch (state changes whenever the switch is toggled)</Help>
5758
<Item label="momentary switch" value="0"/>
5859
<Item label="toggle switch (light on when switch is up/off when down)" value="1"/>
5960
<Item label="toggle switch (state changes whenever the switch is toggled)" value="2"/>
61+
<Item label="garage door (momentary mode for Z-Wave control)" value="3"/>
6062
</Value>
61-
<Value type="list" genre="config" index="3" label="Switch Type for Relay 2 (Sw2)" size="1" min="0" max="2" value="2">
63+
<Value type="list" genre="config" index="3" label="Switch Type for Relay 2 (Sw2)" size="1" min="0" max="3" value="2">
6264
<Help>Switch Type for Relay 2 (Sw2). Choose the wall switch type you want to connect to the Sw2 terminal. Default: toggle switch (state changes whenever the switch is toggled)</Help>
6365
<Item label="momentary switch" value="0"/>
6466
<Item label="toggle switch (light on when switch is up/off when down)" value="1"/>
6567
<Item label="toggle switch (state changes whenever the switch is toggled)" value="2"/>
68+
<Item label="garage door (momentary mode for Z-Wave control)" value="3"/>
6669
</Value>
67-
<Value type="list" genre="config" index="4" label="Switch Type for Relay 3 (Sw3)" size="1" min="0" max="2" value="2">
70+
<Value type="list" genre="config" index="4" label="Switch Type for Relay 3 (Sw3)" size="1" min="0" max="3" value="2">
6871
<Help>Switch Type for Relay 3 (Sw3). Choose the wall switch type you want to connect to the Sw3 terminal. Default: toggle switch (state changes whenever the switch is toggled)</Help>
6972
<Item label="momentary switch" value="0"/>
7073
<Item label="toggle switch (light on when switch is up/off when down)" value="1"/>
7174
<Item label="toggle switch (state changes whenever the switch is toggled)" value="2"/>
75+
<Item label="garage door (momentary mode for Z-Wave control)" value="3"/>
7276
</Value>
7377
<Value type="list" genre="config" index="5" label="LED Indicator Control" size="1" min="0" max="3" value="0">
7478
<Help>LED Indicator Control. Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times. Default: On when all relays are off</Help>
7579
<Item label="On when all relays are off" value="0"/>
7680
<Item label="On when any relays are on" value="1"/>
77-
<Item label="Always On" value="2"/>
78-
<Item label="Always Off" value="3"/>
81+
<Item label="Always Off" value="2"/>
82+
<Item label="Always On" value="3"/>
7983
</Value>
8084
<Value type="int" genre="config" index="6" label="Auto Turn-Off Timer for Relay 1" size="4" min="0" max="65535" value="0" units="minutes">
8185
<Help>Auto Turn-Off Timer for Relay 1. Sets the time (in minutes) after which you want relay 1 to automatically turn off once it has been turned on. Range: 1-65535. Default: 0 (disabled)</Help>
@@ -95,20 +99,59 @@ SPECIFICATIONS:
9599
<Value type="int" genre="config" index="11" label="Auto Turn-On Timer for Relay 3" size="4" min="0" max="65535" value="0" units="minutes">
96100
<Help>Auto Turn-On Timer for Relay 3. Sets the time (in minutes) after which you want relay 3 to automatically turn on once it has been turned off. Range: 1-65535. Default: 0 (disabled)</Help>
97101
</Value>
98-
<Value type="list" genre="config" index="12" label="Enable/Disable Manual Control for SW1" size="1" min="0" max="1" value="1">
102+
<Value type="list" genre="config" index="12" label="Enable/Disable Manual Control for SW1" size="1" min="0" max="2" value="1">
99103
<Help>Enable/Disable Manual Control for SW1. Default: enabled</Help>
100104
<Item label="disabled" value="0"/>
101105
<Item label="enabled" value="1"/>
106+
<Item label="local control disabled with enable on/off reports" value="2"/>
102107
</Value>
103-
<Value type="list" genre="config" index="13" label="Enable/Disable Manual Control for SW2" size="1" min="0" max="1" value="1">
108+
<Value type="list" genre="config" index="13" label="Enable/Disable Manual Control for SW2" size="1" min="0" max="2" value="1">
104109
<Help>Enable/Disable Manual Control for SW2. Default: enabled</Help>
105110
<Item label="disabled" value="0"/>
106111
<Item label="enabled" value="1"/>
112+
<Item label="local control disabled with enable on/off reports" value="2"/>
107113
</Value>
108-
<Value type="list" genre="config" index="14" label="Enable/Disable Manual Control for SW3" size="1" min="0" max="1" value="1">
114+
<Value type="list" genre="config" index="14" label="Enable/Disable Manual Control for SW3" size="1" min="0" max="2" value="1">
109115
<Help>Enable/Disable Manual Control for SW3. Default: enabled</Help>
110116
<Item label="disabled" value="0"/>
111117
<Item label="enabled" value="1"/>
118+
<Item label="local control disabled with enable on/off reports" value="2"/>
119+
</Value>
120+
<Value type="list" genre="config" index="15" label="Auto Turn-Off Timer Unit for Relay 1" size="1" min="0" max="2" value="0">
121+
<Help>Choose between second, minutes, and hours as the unit for Auto Turn-Off time for Relay 1. Default: minutes</Help>
122+
<Item label="minutes" value="0"/>
123+
<Item label="seconds" value="1"/>
124+
<Item label="hours" value="2"/>
125+
</Value>
126+
<Value type="list" genre="config" index="16" label="Auto Turn-On Timer Unit for Relay 1" size="1" min="0" max="2" value="0">
127+
<Help>Choose between second, minutes, and hours as the unit for Auto Turn-On time for Relay 1. Default: minutes</Help>
128+
<Item label="minutes" value="0"/>
129+
<Item label="seconds" value="1"/>
130+
<Item label="hours" value="2"/>
131+
</Value>
132+
<Value type="list" genre="config" index="17" label="Auto Turn-Off Timer Unit for Relay 2" size="1" min="0" max="2" value="0">
133+
<Help>Choose between second, minutes, and hours as the unit for Auto Turn-Off time for Relay 2. Default: minutes</Help>
134+
<Item label="minutes" value="0"/>
135+
<Item label="seconds" value="1"/>
136+
<Item label="hours" value="2"/>
137+
</Value>
138+
<Value type="list" genre="config" index="18" label="Auto Turn-On Timer Unit for Relay 2" size="1" min="0" max="2" value="0">
139+
<Help>Choose between second, minutes, and hours as the unit for Auto Turn-On time for Relay 2. Default: minutes</Help>
140+
<Item label="minutes" value="0"/>
141+
<Item label="seconds" value="1"/>
142+
<Item label="hours" value="2"/>
143+
</Value>
144+
<Value type="list" genre="config" index="19" label="Auto Turn-Off Timer Unit for Relay 3" size="1" min="0" max="2" value="0">
145+
<Help>Choose between second, minutes, and hours as the unit for Auto Turn-Off time for Relay 3. Default: minutes</Help>
146+
<Item label="minutes" value="0"/>
147+
<Item label="seconds" value="1"/>
148+
<Item label="hours" value="2"/>
149+
</Value>
150+
<Value type="list" genre="config" index="20" label="Auto Turn-On Timer Unit for Relay 3" size="1" min="0" max="2" value="0">
151+
<Help>Choose between second, minutes, and hours as the unit for Auto Turn-On time for Relay 3. Default: minutes</Help>
152+
<Item label="minutes" value="0"/>
153+
<Item label="seconds" value="1"/>
154+
<Item label="hours" value="2"/>
112155
</Value>
113156
</CommandClass>
114157

0 commit comments

Comments