ESP32 S2 DA

Miroslav Dzúrik edited this page Aug 2, 2024 · 5 revisions

Desciption

Pinout

The dimensions of the board are 150x122 mm, designed to fit into the UM122 enclosure.

Buttons

Name Meaning Note
BOOT Activate WiFi AP, during restart enter flashing mode ESP gpio0 pin
RESET Restart controller ESP en pin

LEDs

Name Meaning Color Description
WIFI WiFi Blue on - connected to WiFi
flashing (on/off 100/900ms) - Started WiFi AP
flashing (on/off 1900/100ms) - WiFi AP has client connection
CHR Charging Green flashing - vehicle connected but not charging
on - vehicle charging
ERR Error Red on - is in error state (E)
flashing - is in not available state (F)

Terminals

Name Meaning Note
B Detection of the locking actuator
R Control of the locking actuator
W Control of the locking actuator
CP Control Pilot
PP Proximity Plug
GND Ground System ground
12V 12V
OUT1 Low side output 1
OUT2 Low side output 2
OUT3 Low side output 3
OUT4 High side output 1
IN1 Digital input 1
IN2 Digital input 2
IN3 Analog input
GND Ground System ground
DATA 1-Wire bus For external temperature sensor DS18B20
5V 5V power supply
12V 12V power supply
A+ RS-485 A+ pin RS-485 bus with 120Ω terminator resistor
B- RS-485 B- pin RS-485 bus with 120Ω terminator resistor
UART UART serial bus (with 5V power supply)
AR_RLY Relay output for AC contactor
PE Protective Earth Conetected to system ground
N Neutral Neutral conductor, power grid
L Line Phase, power grid
L1 L1 voltage input
L2 L2 voltage input
L3 L3 voltage input
CT1 L1 current transformer
CT2 L2 current transformer
CT3 L3 current transformer
RCM Residual current monitor RCM14-01

Connection examples

L1 - L3 connection is for measuring charging voltage, they are optional.

CT1 - CT3 are current transformers for measuring charging current, they are optional. Can be used any which has ratio 2000/1 (for example: DL-CT08CL5 or SCT-013-000).

When you have setup without current transformers and voltages connection set Energy meter Mode to Dummy, power will be calculated from actual charging current and provided AC voltage.

When you have only current transformers, can be set Energy meter Mode to Current sensing, power will be calculated from measured current and provided AC voltage.

When you have current transformers and voltages connection, can be set Energy meter Mode to Current and voltage sensing, power will be calculated from measured current and voltage.

Remember set Energy meter Three phases depending on whether you have a single-phase or three-phase connection.

Residual Current Monitor (RCM) is optional, if is not available it must be disabled in settings.

With socket outlet

Wiring socket outlet

Set Max charging current to the value of the circuit breaker that protects the EVSE.

With fixed cable

Wiring fixed cable

Set Max charging current to the lower value of the circuit breaker that protects the EVSE or cable maximum current.

Wallbox build

Placed in standard plastic electrical box (300x400x200mm). Based on connection with socket outlet with additional features:

  • Low tariff enable input
  • RCM
  • Nextion display NX4827P043-011C-Y
  • Dragino LoraWAN module

Wallbox

Emergency stop button not wired yet...