PROBLEM:
- UnitError when accessing Parameter.full_value after interface assignment
- Error message: "Expected unit Å, got dimensionless"
- Occurred when accessing: any parameter in any library after redoing bindings of the interface
- Also affected arithmetic operations between parameters
ROOT CAUSE:
- When model.interface = calculator is assigned, generate_bindings() sets up callbacks
- The callback function returns raw numpy.float64 values (dimensionless)
- Parameter.full_value property tries to compare dimensionless callback value with scipp.Variable that has units
- This comparison: scalar != self._scalar triggered UnitError