Column token:
---------------------------------------------------------------------------
A = Active
I = Init (not changeable)
R = Reverse
S = Send not zero values (useful for rotary switches and pushbuttons)
T = Test
LP = Left padding
dM = dimming mode: 0 == off
dT = dimming time interval [sec.]
dV = dimming value
Max = max value (range 0.0 - 1.0 only LED driver 3)
For rotary switches, please check R and S for all positions.
If you check one of these fields:
A = Active
R = Reverse
T = Test
Please select another field. Then the action behind the checkbox is
performed.
Export.lua:
---------------------------------------------------------------------------
Package example: "File=A-10C:163=1.0:171=1.0:179=1.0:47=1.0:586=1.0:"
The delimiter is ':'
Switch/Load a new profile from data package ('File=A-10C:')
The parameter 'A-10C' comes from selfData.Name. The file A-10C.xml will be
loaded.
Log:
---------------------------------------------------------------------------
Modul == 00, Connector == 00 -> Port A ... Arcaze USB
Modul == 00, Connector == 01 -> Port B ... -"-
Modul >= 01, Connector == 00 -> Port C ... LED-Driver
Modul >= 01, Connector == 01 -> Port D ... -"-
Modul >= 01, Connector == 02 -> Port E ... -"-
All values in HEX; Pin numbers in Dez;
Tab 'Configuration'
---------------------------------------------------------------------------
Please, uncheck the checkbox 'log all actions', if you are ready with your
tests and configurations.
Tab 'Display', 'LEDs', 'Switches' and 'Encoders'
---------------------------------------------------------------------------
Both checkboxes 'Active' and 'Init' must checked to get new values from a
record.
Tab 'LEDs'
---------------------------------------------------------------------------
Dimming:
dM = dimming mode: 0 == off
dT = dimming time interval [sec.]
dV = dimming value
For activation of automatic dimming: value > 0.5; dM != 0
Real dimming is only possible with LED-Driver 3, but for other LEDs you get
a automatic blinking.
One more thing: Please use only LED-Driver 2 or LED-Driver 3 on a Arcaze.
Tab 'Masterdata'
---------------------------------------------------------------------------
Table 'Device IDs' and 'Device IDs and Button IDs';
Please look at the files device.lua and clickabledata.lua of your DCS-Modul.
There are all infos you need.
For example look at:
"... \Eagle Dynamics\DCS World\Mods\aircrafts\A-10C\Cockpit\Scripts\ ..."
The infos for gauges are defined in the mainpanel_init.lua.
-
Notifications
You must be signed in to change notification settings - Fork 0
DCS to Arcaze Communicator
License
gargue/DAC
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
About
DCS to Arcaze Communicator
Resources
License
Stars
Watchers
Forks
Packages 0