Skip to content

Scripts to fetch data from IVT REGO2000, Bosch ProControl and Buderus Gateway Logamatic KM200

Notifications You must be signed in to change notification settings

hansliss/regofetcher

Repository files navigation

regofetcher

Scripts to fetch och change data on IVT REGO2000, Bosch ProControl and Buderus Gateway Logamatic KM200 and other equipment based on similar network modules.

NOTE: FHEM has a module called KM200 that should be able to talk to all those units. Give it a try, unless you want to use this as a base for playing around and building your own monitoring tools.

Setting up (if you want to use the logging and monitoring scripts)

This uses Quik for templating, for the notification system: https://github.com/avelino/quik

Copy config.ini.template to config.ini and edit it, adding the information for your particular gateway module. Depending on the vendor, you may have to find the correct vendor key, which is commonly called a "salt", even thought it isn't a salt. Encode the vendor key with Base64.

In order to enumerate valid paths to check on your unit, use the "-x" switch to traverse the tree from one or more starting points, and print out all the recognized leaves. Then you can check each leaf manually to determine what it represents. Use a command like this to enumerate the paths:

python3 getRegoData.py -c config.ini -s myrego -x -p "/,/dhwCircuits,/heatingCircuits,/recordings,/solarCircuits,/system,/gateway,/heatSources,/notifications,/application"

Use the output from this to update the file URLs.txt, which is used by the shell script getVals.sh to fetch the actual data. To initialize the file, you can use this command:

python3 getRegoData.py -c config.ini -s myrego -x -p "/,/dhwCircuits,/heatingCircuits,/recordings,/solarCircuits,/system,/gateway,/heatSources,/notifications,/application" | grep "^scalar:" | sed 's/scalar/scalar:on/' > URLs.txt

Then change any values you don't need to fetch on every run to "off" in the file.

Note that the list of URLs may be different at different times, as the controller enables or disables subsystems. You may want to redo this now and then.

Operation

If you just want to get a value, use e.g.

python3 getRegoData.py -c config.ini -s myrego -p /dhwCircuits/dhw1/charge

This will produce a JSon dump of that particular node, typically including type, accepted values and other info. If you just want to fetch the value, add '-m value':

python3 getRegoData.py -c config.ini -s myrego -p /dhwCircuits/dhw1/charge -m value

If you want to change a simple (writeable) string value, use '-S':

python3 getRegoData.py -c config.ini -s myrego -p /dhwCircuits/dhw1/charge -S start

getVals.sh uses the Python script to fetch individual values according to the list in URLs.txt, and adds an entry to a logfile on CSV format. All the values listed in URLs.txt will be represented as columns in the CSV file, but only the ones marked "on" will be fetched from the gateway.

A new logfile will be created each month. The script also generates a plot of some of the values, using gnuplot. You will want to play around a bit with this.

checkRegoNotifications.sh retrieves any notifications and sends email reminders when there are new ones, or every day while they are active.

Both of these scripts are meant to be run from cron. Here are example crontab entries that will run both scripts in /home/pi/regofetcher every ten minutes:

*/10 * * * * /home/pi/regofetcher/getVals.sh /home/pi/regofetcher/config.ini myrego
5,15,25,35,45,55 * * * * /home/pi/regofetcher/checkRegoNotifications.sh /home/pi/regofetcher/config.ini myrego

Notes

Some examples of parameter formats for "/recordings":

  • ?interval=2018-01-31
  • ?interval=2018-W5
  • ?interval=2018-01

About