Repository navigation
Getting Started Flashing and Configuring the Router
Warning Care must be taken when following these instructions, as it is possible to destroy your router and turn it into a round cornered brick. You have been warned.
Do not attempt to flash the router using a wireless connection to the computer. This will almost certainly brick the router. Use only a wired Ethernet connection.
Introduction There are several different methods of flashing a router and which one is used depends on the router model. Different manufacturers use different methods of upgrading their routers and, in many, cases, a special method must be used to flash to ROOter.
In order to cover all possibilities, a readme.pdf document is included in every image archive that explains the different methods. Also included is a text file that will tell which method to use and any special instructions that may be needed. In this manner the methods used to flash routers is kept up to date.
For those using Wifi to access the router after flashing the default password is rooter2017
When you initially upgrade your router to a ROOter you must reconfigure the router setting to match your needs. This step is not needed when upgrading to a new ROOter version if you had the Keep Settings box checked. If it was unchecked then you must reconfigure it again.
The following are some of the areas that need to be configured in order to make proper use of your ROOter.
For those using Wifi to access the router after flashing the default password is rooter2017
When you first access the web interface of the firmware after flashing it there will be no password set. Just leave the password field blank and continue on to the GUI. The first thing that should be done is to set a password to protect the router. Do this by going to the System menu and the Administration submenu.
Enter the password, confirm it and then click on Save and Apply in the lower right corner. Wait until the changes take place.
At this point we can set the time in the router. Click on the System menu and on the System submenu.
Select the correct Time Zone from the dropdown box, click on Sync with Browser, then click on Save and Apply in the lower right corner. Wait for the changes to take place.
If you plan to use Scheduled Reboot it is critical that you set the Timezone and time correctly for your area. If you don't then the reboot will not take place at the correct time.
By default the ROOter firmware sets the router to have an IP Address of 192.168.1.1. If you wish to change this to another address to avoid conflicts with other devices on your network, select the Network menu and the Interfaces submenu.
In the LAN row, click on the Edit button.
Change the IPv4 address to the IP Address you wish to assign to the router and click on Save & Apply in the bottom right corner. Wait for the changes to be applied.
Since the IP Address has been changed the web interface will stop working and continue to show that the changes are being applied. Wait for a few seconds and then change the URL on your web browser to the new IP Address of the router. You will then be able to log in again, this time using the new IP Address.
Once you have flashed your router to use the ROOter firmware and have finished configuring the router functions, it is time to configure it to use your USB modem.
Do not plug the modem into the router until this configuration is completed. If you are using a PCie or M.2 modem in the router's internal slot then you must reboot the router after the configuration in order for the modem to connect.
Log on to the ROOter web interface and select the Modem menu and Connection Profile submenu.
Rooter uses Profiles to hold the information connected with the modem and how it connects. This allows having different information for different modem and SIM combinations so, once they are set up, you can swap modems or SIMs and still have it connect automatically without changing anything.
If you are using only a single modem and SIM, or multiple modems with the same SIM, then you only need to address the Default Profile. If you use multiple SIMs or are using the Dual Modem feature then you must also use Custom Profile.
We will look at setting up the Default Profile first. This Profile will be used if there is not a Custom Profile to match the modem/SIM combination.
In most cases all that is needed is to fill in the APN which was provided by your ISP. This is required by ROOter as it is needed to make the connection to your ISP's network. If your ISP requires more information in order to connect they will provide that to you and it can be filled in on this tab as well.
If you wish your TimeZone to be set automatically when the modem connects to the Internet change the Auto Set Timezone to Yes. This will attempt to determine your timezone from your connection but it may not always be accurate if your Provider is using servers in a different area.
This is all the information that is needed to make a connection to your Provider's Network. Click on the Save & Apply button in the lower right corner and wait for the changes to be applied. You can now plug the modem into the router and it will automatically make a connection to your Provider's Network. If you are using an internal modem then you must reboot at this point.
If the modem is plugged into the router when you power it up, it will automatically connect to the Provider's Network as soon as the router has finished its boot process.
Any changes made to a Connection Profile will not be applied until the next time the modem attempts to connect, either by plugging in or by rebooting.
Custom Profiles are added as needed by clicking on the ADD button.
This will add a new Custom Profile to ROOter so you can have unique information for a specific modem/SIM combination.
This is similar to the Default Profile except that there is now a section where you can specify exactly which modem or modem/SIM combination will use this profile.
The Custom Profile can be selected by either the modem information (ID, IMEI or name) or by the SIM information (IMSI or ICCID).
The Optional Select allows you to set another selection criteria so that the profile will be used by a very specific modem/SIM combination.
The rest of the fields in a Custom Profile are the same as in the Default profile. Always click Save & Apply after adding or changing a Profile.
The Advanced Tab of a profile is used to configure the modem in different ways from the default method. Some are used for debugging connection problems while others are used when you have dual modems.
Force to PPP Protocol When this is enabled the modem will not use it's normal protocol, such as MBIM or QMI, when connecting but will use the slower PPP protocol. This is used when debugging certain connection problems with new modems.
Connection Delay This is a delay in the connection process that may be needed by some modems while they are connecting. Seldom used or needed these days.
No DHCP for QMI Modems Setting this to Yes will force QMI modems to not use the modem's DHCP but to get that information elsewhere. This can make some QMI modems connect better.
Lock Connection to a Provider This is used to stop a modem from Roaming while it is choosing a tower and ISP. You must know the Country and Network code of your ISP to use this.
Custom DNS Server You can enter the IP Address for up to 4 DNS Servers that will be used instead of those provided by your ISP when the modem connects.
Enable Connection Logging This will show the response to the AT Commands used during the connection process in the System Log. Used for debugging connection problems.
Enable Load Balancing at Connection By default Load Balancing of the modems is disabled as it is not needed for a single modem. If you are using dual modems then this must be enabled to use Load Balancing with them.
Enable Custom AT Startup Command at Connection This allows executing an AT Command immediately after the modem has connected.
Custom AT Startup Command The AT Command to be executed.
Modem Interface Selection This selection is only used in a Custom Profile and is for the use of dual modems. It should be left as Auto when using a single modem. This is used to specify which WAN interface (WAN1 or WAN2) a modem/SIM combination should use when it is detected and connected.
In Auto mode the first modem detected is assigned WAN1 and the second WAN2. When using dual modems this causes a problem because, after rebooting, you can not know which modem will be detected first. Load Balancing requires that you know which modem is using WAN1 and which modem is using WAN2. By specifying which modem/SIM combination will use WAN1 and which one will use WAN2 you can always know which interface is used by which modem.
As always, when making changes to the Advanced Tab click on Save&Apply; to save the changes.
The Connection Monitoring Tab of a profile is used to enable and set up Connection Monitoring for the modem's connection. This will be used to detect when the connection fails and to take certain steps after that happens.
By default, Connection Monitoring is disabled and when you enable it you will show a number of fields that are used for this process. The type of enabling that you choose determines what is done when the connection goes down.
- Enabled - log that a disconnection has occurred in the System Log but take no other action.
- Enabled with Router Reboot - reboot the router if a disconnection occurrs.
- Enabled with Modem Reconnect - try to reconnect the modem using various methods if a disconnect occurrs.
- Enabled with Power Toggle or Modem Reconnect - if supported, power toggle the modem to force a reconnect. Otherwise use other methods to reconnect the modem.
The connection is monitored by pinging a specified site and seeing if there is a response to this ping. Multiple pings can be used and you can customize the ping test to suit your particular connection.
Tracking Reliability It is possible to ping multiple sites in this process and this is the number of those sites that must respond in order to say that the connection is up.
Ping Count The number of pings sent to a site during each test.
Ping Interval The amount of time between sending the pings to a site.
Ping Timeout The number of seconds to wait for a response to a ping test.
Ping Packet Size Size of each ping packet.
Interface Down The number of failed ping tests in a row before the connection is said to be down.
Interface Up The number of successful ping tests in a row before the connection is said to be up.
Tracking IP The IP Address of a site or sites that you wish to ping to determine if the connection is up or down. There must be at least one Tracking IP for Connection Monitoring to work.
The default values will most in most cases but some connections may require changes to suit their specific situation and to eleminate false disconnections.
These files are distributed in the hope that they will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.