IPL outputs of Paula should be open drain #16

Closed
nretro opened this issue Jul 21, 2023 · 0 comments
Closed

IPL outputs of Paula should be open drain #16

nretro opened this issue Jul 21, 2023 · 0 comments

Comments

@nretro
Copy link

nretro commented Jul 21, 2023

I've seen die shots, that suggest, that in a real paula those outputs are open drain. If they where push-pull, the ususal NMI switch (pulling IPL2-IPL0 straight to GND) could kill the IC.

Therefore only 0 or Z should be assigned to ipl_n in Paula.v

nonarkitten added a commit that referenced this issue Aug 8, 2023
Fixes issue #16 IPL outputs are now Z in place of high.