Skip to content

Design Notes

Matt Pare edited this page Dec 28, 2016 · 28 revisions

Positive Voltage Regulator

Bypass Capacitors

It is recommended that the regulator input be bypassed with capacitor if the regulator [...] load capacitance is large. An input bypass capacitor should be selected to provide good high frequency characteristics to insure stable operation under all load conditions. A 0.33 uF or larger tantalum, mylar or other capacitor having low internal impedance at high frequencies should be chosen. The bypass capacitor should be mounted with the shortest possible leads directly across the regulator input terminals.1

No output bypass capacitor is needed for stability but it does improve transient response.1

Reverse Polarity Protection

In addition to protecting against reverse polarity connection caused by operator error or equipment failure, the diodes protect against latch-up problems.

References

1: L7800 Datasheet

Clone this wiki locally