The rectified outputs of D1 (with respect to GND) contain significant ripple that must be smoothed out by large aluminum electrolytic capacitors before reaching the voltage regulator stage of the power supply. Under the following conditions, the value of the capacitors (C) required for a specified ripple voltage (V) can be conservatively approximated as C = I / (f * V).
- Ripple frequency of a full-wave rectified 60 Hz line main is 120 Hz (f) (60 Hz for half-wave).
- Ripple is small compared to output voltage of rectifier D1. Assume 1 Volt peak-to-peak is the specified ripple requirement.
- The downstream voltage regulators appear as constant-current load.
- The discharge of the capacitor is modeled as a ramp.
It is recommended that the regulator input be bypassed with capacitor if the regulator load capacitance is large. An input bypass capacitor should be selected to provide good high frequency characteristics to insure stable operation under all load conditions. A 0.33 uF or larger tantalum, mylar or other capacitor having low internal impedance at high frequencies should be chosen. The bypass capacitor should be mounted with the shortest possible leads directly across the regulator input terminals.2
No output bypass capacitor is needed for stability but it does improve transient response.1
In addition to protecting against reverse polarity connection caused by operator error or equipment failure, the diodes protect against latch-up problems.2