You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Matt Pare edited this page Dec 29, 2016
·
28 revisions
Unregulated Power Supply
Power Supply Filtering
Aluminum electrolytics are used for power supply filtering.1
Positive Voltage Regulator
Bypass Capacitors
It is recommended that the regulator input be bypassed with capacitor if the regulator load capacitance is large. An input bypass capacitor should be selected to provide good high frequency characteristics to insure stable operation under all load conditions. A 0.33 uF or larger tantalum, mylar or other capacitor having low internal impedance at high frequencies should be chosen. The bypass capacitor should be mounted with the shortest possible leads directly across the regulator input terminals.2
No output bypass capacitor is needed for stability but it does improve transient response.1
Reverse Polarity Protection
In addition to protecting against reverse polarity connection caused by operator error or equipment failure, the diodes protect against latch-up problems.2