Fix max_execution_time with cli-server router script #12886
Closed
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
When the cli-server specifies a router script, we run it using zend_execute_scripts instead of php_execute_script, because the former preserves the return value of the script. However, php_execute_script also starts resets the execution timer with the value from max_execution_time. If the timer has previously been initialized with max_input_time, it will never be reset, and thus trigger at the incorrect time.