MC Protocol Library for Node.js

A comprehensive Node.js library for communicating with Mitsubishi PLCs using the MC Protocol. This library provides both JavaScript and TypeScript implementations, inspired by the popular Python pymcprotocol library.

Features

Dual Implementation: Both JavaScript and TypeScript versions
Multiple PLC Support: iQ-R, Q, iQ-L, L, and QnA series
Frame Support: 3E and 4E frame types
Type Safety: Full TypeScript support with type definitions
Modern API: Promise-based with async/await
Batch Operations: Optimized reading/writing of multiple registers
Error Handling: Comprehensive error reporting
Production Ready: Inspired by proven pymcprotocol library

Installation

npm install @raydotac/mcprotocol

Quick Start

TypeScript Usage (Recommended)

import { MCProtocol } from '@raydotac/mcprotocol';

async function main() {
  const plc = new MCProtocol({
    host: '192.168.1.100',
    port: 5002,
    plcType: 'iQ-R'
  });

  try {
    await plc.connect();
    
    // Read single register
    const value = await plc.readRegister('D', 100);
    console.log('D100:', value);
    
    // Read multiple registers (pymcprotocol style)
    const values = await plc.plcRead(['D0', 'D1', 'D2', 'D3', 'D4']);
    console.log('Values:', values);
    
    // Batch read (optimized)
    const batchResult = await plc.batchReadWordUnits([
      { device: 'D', address: 100 },
      { device: 'D', address: 101 },
      { device: 'M', address: 0 }
    ]);
    
    // Write register
    await plc.writeRegister('D', 200, 12345);
    
  } finally {
    await plc.disconnect();
  }
}

JavaScript Usage

const { Type4E, PLC_TYPES } = require('@raydotac/mcprotocol');

async function main() {
  const plc = new Type4E(PLC_TYPES.iQR);
  
  try {
    await plc.connect('192.168.1.100', 5002);
    
    // Read 10 registers starting from D0
    const values = await plc.batchread_wordunits('D0', 10);
    console.log('D0-D9:', values);
    
  } finally {
    plc.close();
  }
}

API Reference

TypeScript API (MCProtocol class)

Constructor Options

interface MCProtocolOptions {
  host: string;           // PLC IP address
  port: number;           // PLC port (usually 5002)
  timeout?: number;       // Connection timeout (default: 5000ms)
  plcType?: 'Q' | 'iQ-R' | 'iQ-L' | 'L' | 'QnA';  // PLC series
  frame?: '3E' | '4E';    // Frame type (default: '3E')
}

Methods

  • connect(): Promise<void> - Connect to PLC
  • disconnect(): Promise<void> - Disconnect from PLC
  • readRegister(device: string, address: number): Promise<number> - Read single register
  • writeRegister(device: string, address: number, value: number): Promise<void> - Write single register
  • plcRead(registers: string[]): Promise<number[]> - Read multiple registers (pymcprotocol style)
  • batchReadWordUnits(addresses: DeviceAddress[]): Promise<ReadResult> - Optimized batch read
  • batchWriteWordUnits(data: WriteData[]): Promise<void> - Optimized batch write

JavaScript API (Type4E class)

Constructor

const plc = new Type4E(plcType);  // plcType: PLC_TYPES.iQR or PLC_TYPES.Q

Methods

  • connect(ip: string, port: number): Promise<void> - Connect to PLC
  • close(): void - Close connection
  • batchread_wordunits(device: string, count: number): Promise<number[]> - Read word units

Supported Devices

Device Description Example
D Data registers D0, D100, D1000
R File registers R0, R100
ZR Extension file registers ZR0, ZR100
M Internal relays M0, M100
X Input contacts X0, X10 (hex)
Y Output contacts Y0, Y10 (hex)
B Link relays B0, B100 (hex)
W Link registers W0, W100 (hex)

Supported PLC Series

  • iQ-R Series: High-performance PLCs (default)
  • Q Series: Standard PLCs
  • iQ-L Series: Compact PLCs
  • L Series: Basic PLCs
  • QnA Series: Legacy PLCs

Error Handling

import { MCProtocolError } from '@raydotac/mcprotocol';

try {
  await plc.readRegister('D', 0);
} catch (error) {
  if (error instanceof MCProtocolError) {
    console.log('PLC Error:', error.message);
    console.log('Error Code:', error.errorCode);
  }
}

Examples

Reading Multiple Device Types

const results = await plc.batchReadWordUnits([
  { device: 'D', address: 0 },    // Data register
  { device: 'M', address: 0 },    // Internal relay  
  { device: 'X', address: 0 },    // Input contact
  { device: 'Y', address: 0 }     // Output contact
]);

Batch Writing

await plc.batchWriteWordUnits([
  { device: 'D', address: 100, value: 1234 },
  { device: 'D', address: 101, value: 5678 },
  { device: 'D', address: 102, value: 9012 }
]);

Using with Different PLC Types

// For Q Series PLC
const qPlc = new MCProtocol({
  host: '192.168.1.100',
  port: 5002,
  plcType: 'Q',
  frame: '3E'
});

// For iQ-L Series PLC  
const iqlPlc = new MCProtocol({
  host: '192.168.1.101', 
  port: 5002,
  plcType: 'iQ-L'
});

Network Configuration

Ensure your PLC has MC Protocol enabled:

  1. iQ-R Series: Enable "MC Protocol" in the Ethernet module settings
  2. Q Series: Configure the Ethernet module for MC Protocol communication
  3. Default Port: 5002 (can be configured in PLC settings)

Comparison with pymcprotocol

This library provides similar functionality to the Python pymcprotocol:

Feature pymcprotocol (Python) This Library (Node.js)
Device Support ✅ D, M, X, Y, R, etc. ✅ D, M, X, Y, R, etc.
PLC Series ✅ iQ-R, Q, L ✅ iQ-R, Q, iQ-L, L, QnA
Frame Types ✅ 3E, 4E ✅ 3E, 4E
Batch Operations ✅ Enhanced
Type Safety ✅ Full TypeScript
Error Handling ✅ Enhanced

Contributing

Contributions are welcome! Please read our contributing guidelines and submit pull requests.

License

MIT License - see LICENSE file for details.

Acknowledgments

  • Inspired by the excellent Python pymcprotocol library
  • Mitsubishi Electric for MC Protocol specifications
  • Community feedback and contributions

Note: This library requires an actual Mitsubishi PLC with MC Protocol enabled for real communication. For testing without hardware, consider using a PLC simulator.