Control line state is not kept per-serial port #4

Closed
rm5248 opened this issue Jul 23, 2016 · 0 comments

Comments

@rm5248
Copy link
Owner

commented Jul 23, 2016

On Windows, the control line state( DTR and RTS ) is a static variable, so if there are multiple serial ports open then when the state of one line changes they will all change.

@rm5248 rm5248 self-assigned this Jul 23, 2016
rm5248 added a commit that referenced this issue Dec 26, 2017
Add code to use per-port DTR/RTS tracking, not global
@rm5248 rm5248 closed this Jan 28, 2018