Skip to content

Simple Device Power Monitoring with Twillio Integration

Notifications You must be signed in to change notification settings

thomasmchen/meter

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

8 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

meter

Simple device power monitoring with Twillio Integration. Requires Twillio SID/Authentication. Recieve an SMS message whenever your device power falls below a specified percentage.

Usage

After cloning the repository, ensure .sh scripts are executable

chmod +x sentinel.sh alert.sh setup.sh

Run the setup.sh script

./setup.sh
Twillio SID: <Enter SID>
Twillio Token: <Enter Token>
Number Recieving Alerts: <Enter # w/ Format +12223334444>

If setup is successful this output will be printed

Setup Complete with <Twillio Number> alerting <Recieving Number>

Note: Twillio trial accounts with only 1 number already provisioned will need to be overridden in .twillio_num after setup.

Scheduling

Schedule sentinel.sh using crontab:

sudo su -
crontab -u <username> -e 

Enter in your crontab statement, for example:

*/5 * * * * sh <Absolute Path To>/sentinel.sh

Note: This schedules a device power check every 5 minutes Test that your statement saved with:

crontab -u <username> -l

Modifying Script

To alter the threshold power % that triggers SMS, simply change the integer in this line in sentinel.sh

if [ "$power" -lt 20 ]

Versioning

Meter adheres to Semantic Versioning 2.0.0. Learn more here. The current version of meter is 0.1.0.